Conventional Soil Absorption SBD-10567-P(86/99) Component Manual Used <br /> 3 Number of Bedrooms <br /> 2 Percent Slope (%) <br /> 90 Depth to Soil Limiting Factor (in.) <br /> 0.7 In Situ soil application rate <br /> 300 Estimated Wastewater Flow ( pd) <br /> 450 Desi n Wastewater Flow ( pd) <br /> 1 Number of System Elevations <br /> 93 Proposed System Elevation #1 <br /> Proposed System Elevation#2 <br /> Proposed System Elevation #3 <br /> 98 Ori final Grade#1 <br /> 98 Finished Grade#1 <br /> Original Grade#2 <br /> Finished Grade#2 <br /> Original Grade#3 <br /> Finished Grade#3 <br /> Infiltrator Quick 4 Standard Chamber Type <br /> 12 Height of Chamber(in.) 19.1 Isq.ft. per chamber <br /> 2 Rows of Chambers 5.8 sq.ft. per pair of end caps <br /> 3 Distance Between Cells (ft.) <br /> 34 Proposed Number of Chambers Used <br /> 642.9 Minimum Distribution Cell Area Required sq.ft. <br /> 661 Distribution Cell Area Proposed (sq.ft.) <br /> Wieser 1000 1 Septic Tank <br /> jPolylok PL-625 jEffluent Filter <br /> Surface Depth to <br /> Soil Boring p Lowest Highest System <br /> Number Grade Limiting Elevation Elevation Elevation <br /> Elevation (ft.) Factor(in.) Acceptable <br /> 1 98.25 120 91.3 97.3 TRUE <br /> 2 97.6 120 90.6 96.6 TRUE <br /> 3 97 120 90.0 96.0 TRUE <br /> 4 3.0 -1.0 FALSE <br /> 5 3.0 -1.01 FALSE <br /> Page of <br />