My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2008/10/14 - SANITARY - SAN - Other
Burnett-County
>
Property Files
>
TOWN OF JACKSON
>
6047
>
2008/10/14 - SANITARY - SAN - Other
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2020 10:11:52 PM
Creation date
10/4/2017 1:08:19 PM
Metadata
Fields
Template:
Property Files v2
Document Date
10/14/2008
Document Type 1
SANITARY
Document Type 2
SAN
Document Type 3
Other
Tax ID
6047
Pin Number
07-012-2-40-15-35-5 05-005-013000
Legacy Pin
012423505900
Municipality
TOWN OF JACKSON
Owner Name
JEFFREY SHANDORF
Property Address
3888 S SHORE RD
City
WEBSTER
State
WI
Zip
54893
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
HOLDING TANK SPECIFICATIONS <br /> Number of bedrooms <br /> Non-residential estimated flow(gpd) <br /> 2000 0 Minimum holding tank volume required (gal) <br /> 2000.0 Proposed holding tank capacity (gal) <br /> Wieser Concrete Tank Manufacturer <br /> WLP2000-MR Tank model number <br /> Level-Alarm Alarm manufacturer <br /> DLV JAlarrn model number <br /> Tank Dimensions and Data Tank Anchor Calculations <br /> 8'x13.67' X for round tank 21120 lbs Weight of tank and cover <br /> 36.0 Liquid depth below inlet invert(in) 1.50 Safety factor <br /> 8.0 Maximum depth of soil cover(ft) 24078 lbs Weight of anchor required <br /> 53.0 Height(in) Outside 23.0 in Soil cover req. for anchor or <br /> 164.0 Length (in) Dimensions 5.9 yd' Concrete counter weight <br /> 96.0 Width (in) Only <br /> HOLDING TANK CROSS SECTION <br /> manhole cover with <br /> �— locking device and finished vent cap <br /> junction warning label rade <br /> box g <br /> �, 12"min. <br /> 24 in. ti <br /> Manhole and vent locations <br /> conduit vent pipe <br /> may be reversed. 18"min. <br /> 12 0 in building sewer <br /> service inlet <br /> blind plug alarm on Note: All tank joints, and <br /> to seal joints between tank <br /> outlet openings and piping are <br /> Electrical as per 24.0 in. sealed watertight. All pipe <br /> NEC 300 and vent materials comply <br /> and Comm 16 with Comm 84. <br /> 3 in. bedding under tank. Tank is anchored as necessary to negate buoyancy. <br /> Project: James and Stacie Shandorf Replacement System <br /> Transaction Number: Page 2 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.