Laserfiche WebLink
Wis nsin Department of Industry, Safety and Buildings Division <br /> Labor&Human Relations INSPECTION REPORT AND ORDERS P.O. Box 7969, Madison, WI 53707 <br /> An inspection of the occupancy shown below discloses violations of orders of the Dept. of Industry, Labor and Human Relations promulgated under <br /> authority of Chapter 101, Wis. Stats. SEE REVERSE SIDE FOR APPLICABLE WISCONSIN STATUTES. Report when orders are completed. Avoid delay. <br /> Forfeiture for unresolved violations are$10.00 to$100.00 each day for each violation. Keep the Department informed. <br /> "Failure of an employer to reasonably enforce compliance by employes with such statute or order of the Department shall constitute failure by the <br /> employer to comply with such statute or order." (s. 102.57, Wis, Stats.) <br /> Inspection Date Plan/Report Number File Number Page <br /> 10/25/93 93-02-1105-B E-134267 1 OF 2 <br /> Inspection Type <br /> ASSEHBLY <br /> Located At(number and street address) <br /> WOOD LAKE BIBLE CAMP 2.2400 ASSEMBLY DRIVE <br /> 22460 ASSEM3LY DRIVE City County <br /> GRANTSBURG WI 54840 GRANTSBURG BURNETT <br /> Violations Explained To <br /> DICK HANSEN <br /> Compliance Date <br /> FEBRUARY, 1 1994 <br /> Note Item Orders and Requirements ✓ Done X Not Done <br /> 1 ILHR 52.04 Swing the door out of the handicapped accessible toilet <br /> (8) compartment in the men's and women's toilet rooms. <br /> 2 ILHR 52.04 Provide at least one mirror and towel dispenser mounted not more <br /> (8)(h) than 40 inches above the floor in the men's and women's toilet <br /> roods. <br /> 3 ILHR 52.20 All electrical work shall conform to the requirements of the <br /> Wisconsin State Electrical Code. <br /> - Provide a cover on the switch above the water pressure tank. <br /> - Maintain at least 3 feet clearance in front of the electrical <br /> panels. <br /> 4 ILHR 51 .047 ,lust the self-closing device on the mechanical room door so <br /> (6) that it completely closes the door. <br /> 5 ILHR 51 ,049 Fill in the openings around the mechanical room door with grout <br /> and around the copper pipes to the sink which pierce the <br /> mechanical room door (adjacent kitchen) . <br /> 6 ILHR 51 .049 Fill in the miscellaneous openings in the walls and ceiling of the <br /> mechanical roor) located to the left of the altar. <br /> 7 ILHR 51 ,049 ,trap the plastic pipe which pierces the mechanical room wall <br /> (adjacent kitchen) with at least 1-inch of noncombustible <br /> insulating material . Mechanically fasten the material to the <br /> pipe. Wrap the pipe for a distance of 3 feet from both faces of <br /> the mechanical room wall . <br /> 3 ILHR 55.33 tiount the portable fire extinguishers. <br /> (3) <br /> Deputy Name Deputy's Office Hours and Telephone Number <br /> SBD-2(R.09190) <br />