POWTS OWNER'S MANUAL U MANAGEMENT PLAN Page Lofr-D <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> Owner -Svw) Septic Tank Capacity /RS-0 gal ❑ Np <br /> Permit# Septic Tank Manufacturer xS' ❑ NA <br /> DESIGN PARAMETERS Effluent Filter Manufacturer _L ❑ NA <br /> Number of Bedrooms ❑ NA. Effluent Filter Model 41oo ❑ NA <br /> Number of Commercial Units NA Pump Tank Capacity gal J*°NA <br /> Estimated flow (average) 1160 gal/day Pump Tank Manufacturer f NA <br /> Design flow (peak), (Estimated x 1.5) <br /> ,60 gal/day pump Manufacturer XNA <br /> Soil Application Rate "oZ- gal/day/ft' Pump Model ANA <br /> Influent/Effluent Quality Monthly average* Pretreatment Unit gNA <br /> Fats, Oil ez Grease (FOG) s30 mg/L ❑ Sand/Gravel Filter ❑ Peat Filter <br /> Biochemical Oxygen Demand (BODS) 5220 mg/L ❑ Mechanical Aeration ❑ Wetland <br /> Total Suspended Solids (TSS) s150 mg/L ❑ Disinfection El Other: <br /> Pretreated Effluent Quality NA Monthly average** Manufacturer <br /> Dispersal Cell(s) <br /> Biochemical Oxygen Demand (BODS) <30 mg/L K In-ground (gravity) ❑ In-ground (pressurized) <br /> Total Suspended Solids (TSS) 530 mg/L ❑ At-grade ❑ Mound <br /> Fecal Coliform (geometric mean) 510' cfu/I00ml O Drip-line ❑ Other: <br /> Maximum Effluent Particle Size A inch diameter <br /> * Values typical for domestic (non-commercial)wastewater and septic <br /> tank effluent. <br /> ** Values typical for pretreated wastewater. <br /> MAINTENANCE SCHEDULE <br /> Service Event Service Frequency <br /> Inspect condition of tank(s) At least once every 3 ❑ months year(s) (Maximum 3 yrs.) <br /> Pump out contents of tank(s) When combined sludge and scum equals one-third (h) of tank volume <br /> Inspect dispersal cell(s) At least once every ❑ months Jif year(s) (Maximum 3 yrs.) <br /> Clean effluent filter At least once every ❑ months g year(s)OAS NEC p -o <br /> Inspect pump, pump controls at.alamt At least once every ❑ months ❑ year(s) J NA <br /> Flush laterals and pressure test At least once every ❑ months ❑ year(s) V<NA <br /> Other: At least once every ❑ months ❑ year(s) ❑ NA <br /> Other: At least once every ❑ months ❑ year(s) [INA <br /> MAINTENANCE INSTRUCTIONS <br /> Inspections of tanks and dispersal cells shall be made by an individual carrying one of the following licenses or certifications: Maste <br /> Plumber, Master Plumber Restricted Sewer, POWTS Inspector, POWTS Maintainer; Septage Servicing Operator. Tank inspections <br /> must Include a visual Inspection of the tank(s) to identify any missing or broken hardware, identify any cracks or leaks, measure the <br /> volume of combined sludge and scum and to check for any back up or ponding of effluent on the ground surface. The dispersal <br /> cell(s) shall be visually inspected to check the effluent levels in the observation pipes and to check for any ponding of effluent on <br /> the ground surface. The ponding of effluent on the ground surface may indicate a failing condition and requires the immediate <br /> notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum in any tank equals one-third (i4) or more of the tank volume, the entire <br /> contents of the tank shall be removed by a Septage Servicing Operator and disposed of in accordance with ch. NR 113, Wisconsin <br /> Administrative Code. <br /> The servicing of effluent filters, mechanical or pressurized POWTS components, pretreatement components, and any other <br /> maintenance or monitoring at Intervals of 12 months or less shall be performed by a certified POWTS Maintainer. <br /> A service report shall be provided to the local regulatory authority within 10 days of completion of any service event. <br /> START UP AND OPERATION <br /> For new construction, prior to use of the POWTS check treatment tank(s) for the presence of painting products or other chemical! <br /> that may Impede the treatment process and/or damage the dispersal cell(s). If high concentrations are detected have the contents <br /> -f't-p t-nblc) romrnipri by i contaop contirinv nnoratnr nrinr to imp <br />