Laserfiche WebLink
WiisconsinDepartment ofIndustry, SOIL AND SITE EVALUATION REPORT Page_of <br /> Labor and Human Relations PAGE 1 OF 3 <br /> Division of Safety 8 Buildings in accord with ILHR 83.05,Wis.Adm. Code <br /> COUNTY <br /> Attach complete site plan on paper not less than 8 1/2 x 11 inches in size.Plan must include,but BURNETT <br /> not limited to vertical and horizontal reference point(BM),direction and%of slope,scale or PARCEL I.D.# <br /> dimensioned, north arrow,and location and distance to nearest road. 12-4234-01 600 <br /> APPLICANT INFORMATION—PLEASE PRINT ALL INFORMATION REVIEW Y DAT <br /> EE 5 0 <br /> P TIMR SHERRY GOVT. OT MEPROPERTY ATIO1 4 NE 1/4,S 34 T 40 N R 15 It(or)W <br /> PIpjFfjYVMS&ffADDRESS LO BLORJt# IIBD. 55 NVA50H9SM IN GOV. LOT 1 <br /> CITY STATE ZIP CODE PHONE NUMBER []CITY nnVILLAGE OSSWNNEAREST ROAD <br /> CRYSTAL, MN 55422 §12) 533-4471 JACKSON PRATT RD. <br /> [ ] New Construction Use F] Residential/Number of bedrooms 2 [ ] Addition to existing building <br /> (R] Replacement [ j Public or commercial describe N/A <br /> gp <br /> Code derived daily flow d <br /> 300 Recommended design loading rate 0'7 bed,gpd/112 0.8 trench,gpd/ft2 <br /> Absorption area required 429 bed,ft2 375 trench,112 Maximum design loading rate 0.7 bed,gpd/ft2 0.8 trench,gpd/ft2 <br /> Recommended infiltration surface elevati2n(s�8'1 — ft (as referred to site plan benchmark) <br /> 36, <br /> Additional design/site considerations CO % <br /> Parent material GLACIAL DRIFT Flood plain elevation,if applicable N/A It <br /> S=Suitable for system CONVENTIONAL MOUND IN GROUND PRESSURE I AT-GRADE SYSTEM IN FILL HOLDING TANK <br /> U=Unsuitable for s stem K]S ❑U :]S ❑U X]S ❑U us ❑U El 31 U El XEI U <br /> SOIL DESCRIPTION REPORT <br /> Depth Dominant Color Mottles Texture Structure ConsistenceBoundairy Roots GPD/ft <br /> Boring# Horizon in. Munsell Qu.Sz.Cont Color Gr. Sz. Sh. Bed Trerxil <br /> `g"� g 1 -6 .5YR 3/2 ROME sl 2msbk fr as 2f 0.5 0.6 <br /> 1 <br /> 2 -20 SYR 5/4 MORE is 08 as if 0.7 0.8 <br /> Ground 3 0-72 OYR 4/3 ROME la Osg 1 --- 0 0.7 0.8 <br /> elev. <br /> 99.8t. <br /> Depth to <br /> limiting <br /> factor <br /> >721, <br /> Remarks: SYSTEM EL. AT 20" <br /> Boring# 1 -6 .SYR 3/2 NOME sl In <br /> fr s 2f 0.5 0.6 <br /> I2 -21 OYR 5/4 ONE is tag a if 0.7 i0.e <br /> 3 1-79 SYR 4/3 ONE is sg 1 -- 0 0.7 0.8 <br /> Ground <br /> IWO,? <br /> Depth to <br /> limiting <br /> Remarks: SYSTEM EL. AT 34" " v <br /> 715 349-2990 <br /> CST Name,.—Please Print REN STRABEL Phone: ( <br /> Address: 7735 AIRPORT ROAD WEBSTER, WI 54893 <br /> Signature: Date: 05-07-1996 CSTNumber1403322 <br />