Laserfiche WebLink
POINTS OWNER'S MANUAL U MANAGEMENT PLAN Page l Ofo <br /> FILE INFORMATION SYSTEM SPECIFICATIONS _ <br /> Owner 'my I Septic Tank Capacity 7sV gal ❑ NA <br /> Permit# t 7Pr 2_,i Septic Tank Manufacturer <br /> l) /F'_VFJ( ❑ NA <br /> DESIGN PARAMETERS Effluent Filter Manufacturer Pot Lo ❑ NA <br /> Number of Bedrooms a 0 NA- Effluent Filter Model L_ a5 ❑ NA <br /> Number of Commercial Units ZONA Pump Tank Capacity gal NA <br /> Estimated flow (average) a0C} gal/day Pump Tank Manufacturer 6e NA <br /> Design flow (peak), (Estimated x 1.5) 3O0 gal/day Pump Manufacturer Ji NA <br /> Soil Application Rate 0. -7 gal/day/ft' Pump Model ILNA <br /> Influent/Effluent Quality Monthly average* Pretreatment Unit X_NA <br /> Fats, Oil 8E Grease (FOG) 530 mg/L ❑ Sand/Gravel Filter ❑ Peat Filter <br /> Biochemical Oxygen Demand (BODS) 5220 mg/L 1:3 Mechanical Aeration 11 Wetland <br /> Total Suspended Solids (TSS) :5 150 mg/L ❑ Disinfection 13 Other: <br /> Manufacturer <br /> Pretreated Effluent Quality )I NA Monthly average** Dispersal Cell(s) <br /> Biochemical Oxygen Demand (BODS) 530 mg/L A In-ground (gravity) ❑ In-ground (pressurized) <br /> Total Suspended Solids (TSS) 530 mg/L ❑ At-grade ❑ Mound <br /> Fecal Coliform (geometric mean) <104 cfu/100m1 1 ❑ Drip-line ❑ Other: <br /> Maximum Effluent Particle Size k inch diameter <br /> * Values typical for domestic (non-commercial)wastewater and septic <br /> tank effluent. <br /> ** Values typical for pretreated wastewater. <br /> MAINTENANCE SCHEDULE <br /> Service Event Service Frequency <br /> Inspect condition of tank(s) At least once every 3 ❑ months year(s) (Maximum 3 yrs.) <br /> Pump out contents of tank(s) When combined sludge and scum equals one-third ('h) of tank volume <br /> Inspect dispersal cell(s) At least once every 3 ❑ months 2 year(s) (Maximum 3 yrs.) <br /> Clean effluent filter At least once every 3 ❑ months I@ year(s) OR 4 lytF_Ar-D <br /> Inspect pump, pump controls 8t:alarm At least once every ❑ months ❑ year(s) ANA <br /> Flush laterals and pressure test At least once every ❑ months ❑ year(s) JQ NA <br /> Other: At least once every ❑ months ❑ year(s) ❑ NA <br /> Other: At least once every ❑ months ❑ year(s) ❑ NA <br /> MAINTENANCE INSTRUCTIONS <br /> Inspections of tanks and dispersal cells shall be made by an individual carrying one of the following licenses or certifications: Master <br /> Plumber, Master Plumber Restricted Sewer, POINTS Inspector, POWTS Maintainer; Septage Servicing Operator. Tank inspections <br /> must Include a visual Inspection of the tank(s) to Identify any missing or broken hardware, identify any cracks or leaks, measure the <br /> volume of combined sludge and scum and to check for any back up or ponding of effluent on the ground surface. The dispersal <br /> cell(s) shall be visually Inspected to check the effluent levels in the observation pipes and to check for any ponding of effluent on <br /> the ground surface. The ponding of effluent on the ground surface may indicate a failing condition and requires the immediate <br /> notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum in any tank equals one-third ('h) or more of the tank volume, the enure <br /> contents of the tank shall be removed by a Septage Servicing Operator and disposed of in accordance with ch. NR 113, Wisconsin <br /> Administrative Code. <br /> The servicing of effluent filters, mechanical or pressurized POWTS components, pretreatement components, and any other <br /> maintenance or monitoring at intervals of 12 months or less shall be performed by a certifled POWTS Maintainer. <br /> A service report shall be provided to the local regulatory authority within 10 days of completion of any service event. <br /> START UP AND OPERATION <br /> For new construction, prior to use of the POWTS check treatment tank(s) for the presence of painting products or other chemicals <br /> that may impede the treatment process and/or damage the dispersal cell(s). If high concentrations are detected have the contents <br /> ,F-t•o 1onlr(0 rommvpA by i confaoo cpnririno nnprntnr nrinr fn mp <br />