POINT LAKE <br /> SUNROOM ADDITION <br /> SPECIFICATIONS <br /> • 14'-0"WIDE X 16'-0"LONG EXTENDING FROM WEST SIDE OF EXISTING HOUSE.AT NW <br /> CORNER. <br /> • 2"X 6"EXTERIOR WALL CONSTRUCTION. <br /> • 9'-0"CEILING HEIGHT. <br /> • WALLS,UNDERSIDE AND CEILING TO BE INSULATED PER STANDARD CONSTRUCTION <br /> CODE. <br /> • SUPPORT POSTS TO BE DETERMINED BY BUILDER FOOTINGS DETERMINED BY <br /> BUILDER IrIINUMM 5 POSTS. <br /> • HARDWARE TO BE BRIGHT BRASS HINGES AND HANDLES.HANDLES TO BE LEVER <br /> TYPE ON FRENCH DOORS. <br /> • WINDOWS ARE TO BE DOUBLE CASEMENT CRANK OUT(BOTH SIDES CRANK OUT) <br /> LOW"E"GLASS WITH ALUMINUM CLAD GREEN EXTERIOR AND PINE INTERIOR. <br /> SCREENS TO BE INCLUDED. <br /> • WINDOWS TO BE 4'-6"HIGH BY 4'-0"WIDTH.FIVE(5)T)BE PROVIDED. <br /> • REMOVE EXISTING 4'-0"WIDE SLIDER WINDOW IN KITCHEN. <br /> • ENTRY TO ROOM TO BE 4'0"DOUBLE WIDE INTERIOR FRENCH DOORS(BOTH DOORS <br /> OPEN)WITH GRILLED WINDOWS AND PLACED IN OPENING CREATED BY REMOVAL OF <br /> KITCHEN WINDOW. <br /> • REMOVED WINDOW TO BE INSTALLED IN CENTER OF SOUTH FACING WALL. <br /> ADD LINEN CLOSET AT S.E.CORNER SIZE TO BE 2'-0"DEEP INSIDE X 4'-0"WIDE X <br /> CEILING HEIGHT.DOORS TO BE LOUVERED BIFOLD.SHELVING TO BE WIRE STYLE. <br /> • ROOF PITCH EXISTING APPROX.8X12 WITH INSIDE VAULT CEILING 4X12.ADD FLAT <br /> APPROXIMATELY 3'WIDE AT INTERIOR PEAK.SIMILAR TO EXISTING. <br /> • SHINGLES TO MATCH EXISTING. <br /> • ALUMINUM FACIA AND SOFFIT TO MATCH EXISTING. <br /> • EXTERIOR VINYL,SIDING TO BE PROVIDED BY CUSTOMER INSTALLED BY <br /> CONTRACTOR <br /> • SKIRT BOARDS(IF REQUIRED)TO BE CEDAR TO MATCH EXISTING CEDAR DECKING. <br /> EXISTING CEDAR DECK TO BE REMOVED AND REMAINING TO BE PROPERLY FINISHED <br /> AND SUPPORTED. <br /> • INTERIOR OF ROOM TO BE ALL KNOTTY PINE PRE-FINISHED AND SEALED.INCLUDING <br /> TRIM AND DOOR <br /> • FLOORING LAMINATE TO BE PROVIDED BY CUSTOMER INSTALLED By CONTRACTOR <br /> INSTALLATION NOT IN BID. <br /> • UNDERSIDE OF ADDITION TO BE INSULATED AND COVERED WITH TREATED <br /> PLYWOOD SCREWED IN PLACE. <br /> • FORCED AIR HEAT/COOL TO BE PROVIDED FROM EXISTING DUCT RUN IN BASEMENT. <br /> MINIMUM TWO(2)7"SUPPLY DUCTS AND 1 RETURN.NOT INCLUDED IN CONTRACTOR <br /> BID. <br /> 15 AMP ELECTRICAL TO BE BROUGHT FROM EXISTING SERVICE BOX.NUMBER OF <br /> OUTLETS PER CODE. 1 CEILING FAN W/LIGHT BOX AND SWITCH TO BE PROVIDED.ADD <br /> 2 CEILING LIGHT CANS WITH SWITCH AND 1 PULL CHAIN LIGHT IN CLOSET, <br /> ELECTRICAL TO BE ROUGHED IN ONLY. <br /> • 1 PHONE OUTLET AND CABLE OUTLET TO BE INCLUDED.CABLE TO BE RUN TO <br /> UTILITY AREA AND ENDED WITH OTHERS. <br /> • LEAF GUARD OR EQUIVALENT GUTTERS TO BE ADDED ON NORTH AND SOUTH SIDES <br /> OF ADDITION.NOT IN CONTRACTOR BID. <br /> SPECIFICATIONS ARE FOR REFERENCE ONLY.CONTRACTOR TO DETERMINE ALL <br /> STRUCTURAL REQUIREMENTS.7-28-2007.REVISED 9-5-07. <br />