Laserfiche WebLink
HOLDING TANK SPECIFICATIONS <br /> Single Tank Option <br /> Complete Red Boxes Only In-pounds Metric <br /> If one-or two-family, number of bedrooms= 0 <br /> And/Or....Non-residential flow per day = 322 gpd or 1219 Lpd <br /> Minimum holding tank volume required= 2000.0 gal or 7570 L <br /> Holding tank capacity proposed2,000 gal or 7570 L <br /> Manufacturer Wieser Concrete Products <br /> Alarm manufacturer IVector Mfg <br /> Alarm model number IDLV high water float <br /> Depth from inlet invert to service alarm= 12.0 in or30.5 cm <br /> Liquid depth of tank below inlet invert = 43.0 in or 109.2 cm <br /> HOLDING TANK CROSS SECTION nicking eviceacover d <br /> lacking device and <br /> — -- warning label <br /> finished junction <br /> vent gee <br /> cap 12"(30 cm)min. <br /> — vent pipe V conduit -> 18^(as cm) <br /> Electrical as per NEC 300. <br /> 12.0 in. or building sewer <br /> \ <br /> 30.5 ( service inlet <br /> blind plug - alarm on <br /> to seal_ <br /> outlet <br /> Manhole and vent 31.0 in. or <br /> may be reversed. 78.7 cm <br /> 3 in.(8 cm)bedding under,tank. <br /> Tank anchored as necessary to negate buoyant forces. <br /> Note: All tank joints, and joints between tank <br /> openings and piping are sealed water tight. <br /> Project: Kevin Karge holding tank <br /> Plan I.D.: S96-21222 Page 2 of <br />