Laserfiche WebLink
Single Holding Tank Cross Section and Plan View <br /> Plan View <br /> Typical <br /> 24" I.D. <;< <br /> Inlet / Manhole Vent Pipe Y <br /> >; Opening <br /> > <br /> Cross-Section <br /> 4 in. Dia. <br /> Finished Grade — — _ ._ _ ,_ _ _ Vent with <br /> Min. 4" I Cap 12" <br /> Above i Above <br /> Grade With +5 Ft Cover - Grade <br /> Locking Manhole Cover <br /> Sealed Watertight <br /> Device <br /> > Y <br /> Tether Tank Manufacturer: <br /> > <br /> t Weight < <br /> l' Tank Capacity: Gallons <br /> Tank Maximum Depth of Bury: Ft <br /> Alarm ` <br /> Switch Depth of Soil Cover Over Tank 2 Ft. <br /> (ln <br /> �<y Tank Outside Dim.: Width Ft, Length Ft, <br /> Ft <br /> Height _ '< <br /> >( <br /> Ye> Y( <br /> °> Alarm Switch Type: El Mercury ❑Mechanical <br /> ( <br /> '<'<'t'<'('<,<'<'<'<'<'t'<'<'<'<><'<><><>t'i'<,<><><'{><><><><'i?<}< <br /> GENERAL INSTIALLATION: The tank is bedded and back filled in accordance with the <br /> manufacturer's proWci apyNoval specifications. Maximum depth of bury as specified by the <br /> manufacturer may not be exceeded without prior approval. Manhole covers exposed to grade have an <br /> effective locking device (padlock) installed. Manhole covers below grade are sealed watertight. Piping at <br /> the inlet is of approved material, connected to the tank with watertight fittings, and laid on stable soil to <br /> prevent settling or sagging. Electrical is as per the National Electrical Code and applicable Wisconsin <br /> standards. . Electrical is as per the National Electrical Code and applicable Wisconsin standards. <br /> 03/05 19j Page of <br />