1 <br /> POWTS OWNER'S MANAGEMENT PLAN <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> OWNER Paul Reis Septic Tank Capacity 1000 Gal. <br /> PERMIT# <br /> Septic Tank Manufacturer Wieser Concrete <br /> Effluent Filter Manufacturer Pol lok <br /> DESIGN PARAMETERS Effluent Filter Model PIr525 [I n/a <br /> Number of Bedrooms 3 Pump Tank Capacity NA <br /> Number of Commercial Units — Pump Tank Manufacturer NA <br /> Estimated Daily Flow 300 gal/day Pump Manufacturer NA <br /> Design Flow(Peak) Est.x 1.5 450 gal/day Pump Model NA <br /> Soil Application Rate .7 gal/day/ft' Pretreatment Unit ❑ n/a <br /> Influent/Effluent Quality Monthly Average ❑ Sand/Gravel Filter I I Peat Filter <br /> Fats,Oils&Grease(FOG) <30 mg/L ❑ Mechanical Aeration ❑ Wetland <br /> Biochemical Oxygen Demand(BODS) <_220 mg/L ❑ Disinfection ❑ Others: <br /> Total Suspended Solids TSS < 150 mg/L <br /> Pretreated Effluent Quality I I n/a Monthly Average Dispersal Cell(s) 2 <br /> Biochemical Oxygen Demand (BODS) <30 mg/L X in-ground gravity ❑ In-ground(pressurized) <br /> Total Suspended Solids(TSS) <30 mg/L ❑ At-grade ❑ Mound <br /> Fecal Coliform (geometric mean) 510"cfu/l00m1 ❑ Drip-line ❑ Other: <br /> Maximum Effluent Particle Size /.inch diameter Infiltrator Quick 4 Standard-W Eisa Rating 20 <br /> MAINTENANCE SCHEDULE <br /> SERVICE EVENT SERVICE FREQUENCY <br /> Inspect condition of tanks At least once every I I months 3 year s) Maximum 3 ears <br /> Pum out contents of tank(s) When combined sludge and scum equals one-third(/3)of tank volume <br /> Inspect dispersal cells At least once every ❑ months 3 year(s) (Maximum 3 ears <br /> Clean effluent filter At least once every ❑months 1 year(s) or as needed <br /> Inspect pump,pump controls and alarm At least once every ❑ months 1 year s ❑ n/a <br /> Maintenance Instructions <br /> Inspections of tanks and dispersal cells shall be made by a individual carrying one of the following licenses or certifications: Master <br /> Plumber;Mater Plumber Restricted Sewer;POWTS Maintainer,Septage Servicing Operator. Tank inspection must include a visual <br /> inspection of the tank(s)to identify any missing or broken hardware,identify any cracks or leaks,measure the volume of combined <br /> sludge and scum and to check for any back up or ponding of effluent on the ground surface. The dispersal cell(s)shall be visually <br /> inspected to check the effluent levels in the observation pipes and to check for any ponding of effluent on the ground surface. The <br /> ponding of effluent on the ground surface may indicate a failing condition and requires the immediate notification of the local <br /> authority. <br /> When the combined accumulation of sludge and scum in any tank equals one-third(`/3)or more of the tank volume,the entire <br /> contents of the tank shall be removed by a Septage Servicing Operator and disposed of in accordance with ch.NR 113, Wisconsin <br /> Administrative Code. <br /> The servicing of effluent filters,mechanical or pressurized POWTS components,pretreatment components,and any other <br /> maintenance or monitoring at intervals of 12 months or less shall be performed by a certified POWTS Maintainer. <br /> A service report shall be provided to the local regulatory authority within 10 days of completion of any service event. <br /> START UP AND OPERATION <br /> For new construction,prior to use of the POWTS check treatment tank(s)for the presence of painting products or other chemicals that <br /> may impede the treatment process and/or damage the dispersal cell(s). If high concentrations are detected have the contents of <br /> the tank(s)removed by a septage servicing operator prior to use. <br />