Laserfiche WebLink
HOLDING TANK SPECIFICATIONS <br /> 2 Number of bedrooms <br /> Non-residential estimated flow(gpd) <br /> 2000.0 Minimum holding tank volume required (gal) <br /> 2000.0 Proposed holding tank capacity (gal) <br /> Wieser Concrete Tank Manufacturer <br /> WLP2000-MRHD Tank model number <br /> SJ Electro Alarm manufacturer <br /> HW 101 JAlarm model number <br /> Tank Dimensions and Data Tank Anchor Calculations <br /> X for round tank 22230 lbs Weight of tank and cover <br /> 36.0 Liquid depth below inlet invert (in) 1.50 Safety factor <br /> 3.0 Maximum depth of soil cover(ft) 22968 lbs Weight of anchor required <br /> 53.0 Height (in) Outside 22.0 in Soil cover req. for anchor or <br /> 164.0 Length (in) Dimensions 5.7 yd Concrete counter weight <br /> 96.0 Width (in) I Only <br /> HOLDING TANK CROSS SECTION <br /> manhole cover with <br /> locking device and finished 16 vent cap <br /> junction warning label grade <br /> box —� — <br /> 24 in. <br /> 4"min. 1 t <br /> jr 12"min. <br /> � � <br /> Manhole and vent locations <br /> conduit —� may be reversed. vent pipe 18"min. <br /> y <br /> 12.0 In. building sewer <br /> service — � — ----- — — — — — inlet <br /> blind plug alarm on Note: All tank joints, and <br /> to seal joints between tank <br /> outlet openings and piping are <br /> Electrical as 24.0 in. sealed watertight. All <br /> per NEC 300 pipe and vent materials <br /> and Comm 16 comply with Comm 84. <br /> 3 in. bedding under tank Tank is anchored as necessary to negate buoyancy <br /> Project: Walsh <br /> Transaction Number: Page 2 of 5 <br />