Laserfiche WebLink
CONTINGENCY PLAN MANAGEMENT PLAN DOMESTIC WASTEWATER <br /> --�INGROtIND SYSTEM PURSUANT SPS 83.54 ADM. CODE POWTS <br /> SHALL INCLUDE INFO. AND PROCEDURES <br /> ----- AT-GRADE SYSTEM FOR MAINTAINING THE SYSTEM WITHIN <br /> CURRENT CODES. THIS MGMT PLAN COMPLIES <br /> ----- MOUND SYSTEM WITH COMM. 83.54 WI ADMIN. CODE AND THE <br /> INGROUND SOIL OBSORPTION COMPONENT <br /> --�-- HOLDING TANK MANUAL SBD-10705-P (N.01/01 VERSION 2) <br /> --'-- ALTERNATE AREA PROVIDED AS TABLE 1 <br /> EVIDENCED WITH ADDED PITS/BORINGS NUMBER OF BEDROOMS 3 <br /> ----- MOUND SYSTEM REPLACEMENT OF DESIGN FLOW-PEAK (GPD) "O <br /> DRAINFIELD WITHIN EXISTING LOCATION ESTIMATED FLOW-AVG. (GPD) 300 <br /> ----- REPLACE EXISTING HOLDNG TANK <br /> WITH NEW TANK SEPTIC TANK CAPACITY (GAL) LOOD �(,t5� <br /> 32A ��FwTPJt-�,��� <br /> ----- ALTERNATE AREA DOES NOT EXIST CELL/ GRAINFIELD SIZE (vj'� <br /> BY LACK OF AREA. HOLDING TANK OR <br /> NEW TECHNOLOGY SYSTEM TO BE TABLE 2 <br /> INSERTED INTO EXISTING SYSTEM DESIGN FLOW PEAK (TANK) ASO <br /> CELUFEILD COMPONENT (05� <br /> �e 5-t<�(Z 'I'Jc 3 0�$ <br /> SEPTIC TANK <br /> THE SEPTIC TANK SHALL BE MAINTAINED BY A CERTIFIED TO SERVICE TANKS UNDER <br /> S281.48 STATS. THE CONTENTS OF THE TANK SHALL BE DISPOSED OF IN <br /> ACCORDANCE WITH NR113 WI. ADM. CODE <br /> THE OPERATING CONDITION OF THE SEPTIC TANK AND FILTER SHALL BE ASSESSED <br /> �/ONCE EVERY 3 YEARS BY PUMPING AND/OR INSPECTION. THE OUTLET BAFFLE FILTER <br /> SHALL BE CLEANED AS NEEDEDTO ENSURE PROPER OPERATION OF POWTS SYSTEM. <br /> THE FILTER CARTRIDGE SHOULD NOT BE REMOVED UNLESS PROVISIONS ARE MADE <br /> TO SOLIDS > THAN 1/8" REMAIN IN TANK. IF TRHE FILTER IS EQUIPPED WITH AN ALARM, <br /> THE FILTER SHALL BE SERVICED IF THE ALARM IS ACTIVATED INTERMITTENTLY OR <br /> CONTINUOUSLY. THE SEPTIC TANK SHALL HAVE ITS CONTENTS REMOVED WHEN THE <br /> VOLUME OF SLUDGE AND SCUM IN THE TANK EXCEEDS 1!3 THELIQIOD CAPACITY OF <br /> THE TANK. IF CONTENTS ARE NOT REMOVED FAILURE OF SYSTEM MAY RESULT. <br /> START UP AND OPERATION <br /> NEW CONSTRUCTION: TANKS SHOULD BE INSPECTED FOR PRESENCE OF PAINTING. <br /> OR CHEMICRL (DRYWALL DUSIlTHESE CHEMICALS WILL IMPEDE OR DAMAGE POWTS <br /> IF CONCENTRATIONS ARE DETECTED TANK MUST BE PUMPED BY LICENSED PUMPER <br /> DO NOT DRIVE OR PARK AUTOS OVER TANKS OR CELLS. <br /> DO NOT DRIVE OR DISTURB THE AREA WITHIN 15 FT OF THE DOWNSLOPE TOES OF <br /> ANY MOUND OR AT-GRADE SOIL ABSORPTION AREA <br /> ABANDONEMENT: WHEN THE POWTS SYSTEM IS REMOVED FROM SERVICE THE <br /> COMPONENT MUST BE ABANDONED IN COMPLIANCE WITH 83.33 WI ADM. CODE <br /> ALL PIPING MUST BE DISCONNECTED AND OPENINGS SEALED, CONTENTS MUST BE <br /> REMOVED AND PROPERLY DISPOSED OF BY SERVICING OPERATOR AND TANKS/PITS <br /> COVERS ARE TO BE REMOVED AND VOID SPACE FILLED WITH SOIUSOLID MATERIAL. <br />