Laserfiche WebLink
HOLDING TANK SPECIFICATIONS <br />3 Number of bedrooms <br />Non-residential estimated flow (gpd) <br />Minimum holding tank volume required (gal) <br />2000.0 1 Proposed holding tank capacity (gal) <br />Wieser Conrete Tank Manufacturer <br />WLP2000-MR Heavy Duty Tank model number <br />SJE Rombus Alarm manufacturer <br />Tank Alert 1 Alarm model number <br />Tank Dimensions and Data <br />Tank Anchor Calculations <br />X for round tank <br />36.0 <br />Liquid depth below inlet invert (in) <br />8.0 <br />Maximum de th of soil cover (ft) <br />53.0 <br />Height (in) <br />in Soil cover req. for anchor or <br />164.0 <br />Length (in) <br />96.0 <br />Width (in) <br />Tank Anchor Calculations <br />19430 <br />lbs Weight of tank and cover <br />1.50 <br />Safety factor <br />25768 <br />lbs Weight of anchor required <br />28.3 <br />in Soil cover req. for anchor or <br />6.4 <br />yds Concrete counter weight <br />HOLDING TANK CROSS SECTION <br />manhole cover with <br />locking device and finished vent cap <br />junction warning label grade <br />box <br />, 4" min. 1. f_ 12' min. <br />< 23 in. <br />Manhole and vent locations <br />conduit —� vent pipe <br />18" min. <br />tether weight <br />bservice <br />blind plug alarm on <br />to seal <br />outlet <br />Electrical as per <br />NEC 300 <br />and SPS 316 <br />3 in. bedding under tank. <br />12.0 in. <br />24.0 in. <br />Note: All tank joints, and <br />joints between tank <br />openings and piping are <br />sealed watertight. All <br />pipe and vent materials <br />comply with SPS 384. <br />Tank is anchored as necessary to negate buoyancy. <br />building sewer <br />inlet <br />Project: William Lunzer <br />Transaction Number: Page 2 of j <br />