Laserfiche WebLink
Safety and Buildings <br /> 10541N RANCH ROAD <br /> HAYWARD WI 54843 <br /> TDD#:(608)264-8777 <br /> ` www.commerce.state.wi.us <br /> isconsin Tommy G.Thompson,Governor <br /> Department of Commerce Brenda J.Blanchard,secretary <br /> September 28,2000 <br /> CUST ID No.225851 ATTN:POWTS INSPECTOR <br /> ZONING OFFICE <br /> RICHARD HOPKINS BURNETT COUNTY SPIA <br /> 2 7410 CTH K#102 <br /> 7760 HWY 35 <br /> WEBSTER WI 54893 SIREN WI 54872 <br /> RE: CONDITIONAL APPROVAL Identification Numbers <br /> PLAN APPROVAL EXPIRES: 09/28/2002 Transaction ID No.435498 <br /> Site ID No. 170848 <br /> Please refer to both identification numbers, <br /> SITE: above,in all comes ondence with the a enc . <br /> Site ID: 170848, WILDWOOD ESTATES <br /> BURNETT County,Town of OAKLAND;CTY RD U <br /> ,S20,T40N,RI6W <br /> WILDWOOD ESTATES-SITES 19-26 CTY RD U <br /> FOR: <br /> Object Type:POWT System Regulated Object ID No.:761767 <br /> The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes <br /> and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner,as defined in <br /> chapter 101.01(10),Wisconsin Statutes,is responsible for compliance with all code requirements. <br /> The following conditions shall be met during construction or installation and prior to occupancy or use: <br /> 1. This plan action is subject to designer comments on the plan. <br /> 2. The maintenance plan for this system must be given to the owner of the POWTS. p <br /> 3. This approval does not include plans for the general plumbing systems or sewer piping leading to the C(I12I{' <br /> project. See section COMM 82.20,Wis.Adm.Code,to <br /> septic/holding tank that may be required for this g " <br /> determine if plan submittal and approval is required. x,11 <br /> 4. The observation pipes shall be located at opposite ends of the distribution cell at a distance of , <br /> approximately equal to 1/6 the distribution cell length. ARYME <br /> 5. There must be a minimum of 3' between the soil absorption cells per the In Ground Soil Absorption ^ <br /> Manual. by" <br /> t backs per COMM 83.43(8)(1). <br /> 6. Maintain well and waterline se <br /> 7. The designer intends to install 2 Skaw 2570 gallon septic tanks and proposes a service interval of 3 yea SEE GC <br /> The Maintenance Manual should be amended to reflect this proposed service interval. <br /> 8. Bed tanks per COMM 83.45(5). <br /> A copy of the approved plans,specifications and this letter shall be on-site during construction and open to <br /> inspection by authorized representatives of the Department,which may include local inspectors. All permits <br /> required by the state or the local municipality shall be obtained prior to commencement of <br /> construction/installation/operation. <br />