Page 4 of 6 <br /> Combination Tank Component Cross Section <br /> Approved Manhole Covers With Waring Labels <br /> and Locking Device/4"Min.Above Final Grade <br /> \ Weather Proof Junction Box <br /> Electric per NEC 300& SPS. <br /> >or= <br /> to 12" <br /> 4" Vent / 316.012WAC <br /> = 1f <br /> Above Final Grade y <br /> Disco <br /> Alternate Outlet Location <br /> W/Approved 4" Sleeve <br /> Inlet Approved Force Main Diam.= 2 " <br /> Effluent Filter <br /> Batlle <or=to 1/8" Weep Hole or Anti Siphon Device <br /> Particle Size A <br /> WLP1000/600-MR <br /> B Pump Off Elev. 963.83' <br /> Wieser C <br /> Tank Mfr. Concrete <br /> D rA 963.00' <br /> Dose Tank Elev. <br /> Vertical Difference Between Pump Off and Distribution Pipe= 6.32' <br /> Minimum Required Supply Pressure......................................= Na <br /> 32 FT.of Force Main x 1.94 Friction Factor/100FT. ..._ .58 <br /> Total Dynamic Head....................= 6.90' <br /> Number of Doses...= 5.54 Per Day Gal.Per Day/#of Doses= 86.96 Gal. <br /> Volume of Backflow....................................................................= 5.22 Gal. <br /> TotalDose Volume..................................................................... = 92.18 Gal. <br /> Pump Tank Capacity 60336 Gallons Dimensions Inches Gallons <br /> Pump Tank Volune 16.76 Gal/Inch A 18.50 310.06 <br /> Pump Mfr. Zoeller B 2 33.52 <br /> Pum Model 152 C 5.50 92.18 <br /> P D 10 167.60 <br /> Minimum Discharge Rate= Na GPM <br /> Alarm Mfr. S.J.E.Rhombus Total= 36 603.36 <br /> Alarm Model Tank Alert 1 <br /> Bed Tank per SPS.383.45(5) <br /> Anchor Tank as necessary to negate buoyant forces per SPS.383.43(8xg). <br /> Note: Pump Controls and Alarm Switch require separate circuits. <br />