Page 6 of 6 1-2 <br /> 1 <br /> POWTS OWNER'S MANAGEMENT PLAN <br /> FILE INFORMATION SYSTEM SPECIFICATIONS <br /> OWNER Daniel McPhillips Septic Tank Capacity 1000 Gal. _ <br /> PERMIT# Septic Tank Manufacturer Wieser Concrete <br /> Effluent Filter Manufacturer Lifetime <br /> DESIGN PARAMETERS Effluent Filter Model LT 1/8 <br /> Number of Bedrooms 3 Pump Tank Capacity 600 <br /> Number of Commercial Units — Pump Tank Manufacturer Wieser Concrete <br /> Estimated Daily Flow 300gal/day Pump Manufacturer Zoeller <br /> Design Flow(Peak)(Est.x 1.5 450gal/day Pump Model 152 <br /> Soil Application Rate .7 al/da /ft2 pretreatment Unit n/a <br /> Influent/Effluent Quality Monthly Average I Sand/Gravel Filter Peat Filter <br /> Fats,Oils&Grease(FOG) <30 mg/L 1 Mechanical Aeration i Wetland <br /> Biochemical Oxygen Demand(BODS) <220 mg/L <br /> Total Suspended Solids(TSS) _<150 m l Disinfection 1 Others: <br /> Pretreated Effluent Quality I n/a Monthly Average Dispersal Cell(s) 2 Aggregate Cells-w-Lift Pump <br /> Biochemical Oxygen Demand (BODS) <_30 mg/L X in-ground gravity i In-ground(pressurized) <br /> Total Suspended Solids(TSS) <_30 mg/L At-grade Mound <br /> Fecal Coliform (geometric mean) <_104 cfU/100m1 <br /> Drip-line Other: <br /> Maximum Effluent Particle Size L %inch diameter Infiltrator Quick 4 Standard-W <br /> MAINTENANCE SCHEDULE <br /> SERVICE EVENT SERVICE FREQUENCY <br /> Inspect condition of tank(s) At least once eve I months 3 year(s) (Maximum 3 years) <br /> Pump out contents of tanks When combined sludge and scum equals one-third /3 of tank volume <br /> Inspect dispersal cell(s) At least once every months 3 year(s) (Maximum 3 ears) <br /> Clean effluent filter At least once every months 1 year(s) or as needed <br /> Inspect pump,pump controls and alarm At least once every months 1 year(s) n/a <br /> Maintenance Instructions <br /> Inspections of tanks and dispersal cells shall be made by a individual carrying one of the following licenses or certifications: Master <br /> Plumber;Mater Plumber Restricted Sewer;POWTS Maintainer;Septage Servicing Operator. Tank inspection must include a visual <br /> inspection of the tank(s)to identify any missing or broken hardware,identify any cracks or leaks,measure the volume of combined <br /> sludge and scum and to check for any back up or ponding of effluent on the ground surface. The dispersal cell(s)shall be visually <br /> inspected to check the effluent levels in the observation pipes and to check for any ponding of effluent on the ground surface. The <br /> ponding of effluent on the ground surface may indicate a failing condition and requires the immediate notification of the local <br /> authority. <br /> When the combined accumulation of sludge and scum in any tank equals one-third(1/3)or more of the tank volume,the entire <br /> contents of the tank shall be removed by a Septage Servicing Operator and disposed of in accordance with ch.NR 113, Wisconsin <br /> Administrative Code. <br /> The servicing of effluent filters,mechanical or pressurized POWTS components,pretreatment components,and any other <br /> maintenance or monitoring at intervals of 12 months or less shall be performed by a certified POWTS Maintainer. <br /> A service report shall be provided to the local regulatory authority within 10 days of completion of any service event. <br /> START UP AND OPERATION <br /> For new construction,prior to use of the POWTS check treatment tank(s)for the presence of painting products or other chemicals that <br /> may impede the treatment process and/or damage the dispersal cell(s). if high concentrations are detected have the contents of <br /> the tank(s)removed by a septage servicing operator prior to use. <br />