Laserfiche WebLink
September 18, 2017 <br />CUST ID No. 224059 <br />KEITH E STONER <br />KEITH STONER SOIL TESTING SANITARY DESIGN <br />23220 WOODCREEK RD <br />SIREN WI 54872-8728 <br />CONDITIONAL APPROVAL <br />PLAN APPROVAL EXPIRES: 09/18/2019 <br />SITE: <br />That Hwy 70 Campground (Southwest System) <br />6910 Sth 70 <br />Town of Meenon <br />Burnett County <br />FOR: <br />DIVISION OF INDUSTRY SERVICES <br />2331 SAN LUIS PL STE 150 <br />GREEN BAY WI 54304-5211 <br />Contact Through Relay <br />hftp://dsps.wi.gov/programs/industry-services <br />www.wisconsin.gov <br />ATTN.- POWTS Inspector <br />ZONING OFFICE <br />BURNETT COUNTY SPIA <br />Scott Walker, Governor <br />Laura Gutl6rrez, Secretary <br />CONDITIG <br />APPRC <br />C� PT OF SA <br />10 NA <br />7410 CTH K #102 �Z <br />�/ / � <br />SIREN WI 54872 <br />Identification Numbers <br />Transaction ID No. 2994869 <br />Site ID No. 842381 <br />Please refer to both identification numbers, <br />above, in all correspondence with theagency. <br />Description: SOUTHWEST SITES SYSTEM- Dosing In -Ground <br />Object Type: POWTS Component Manual Regulated Object ID No.: 1727477 <br />Maintenance required, 1,575 GPD Flow rate; 64 in Soil minimum depth to limiting factor from original grade; <br />System(s): In -ground POWTS Component - Ver. 2.0, SBD -10705-P (N.01/01, R. 10/12); Effluent Filter <br />The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes <br />and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. This system is to be constructed <br />and located in accordance with the enclosed approved plans and with any component manual(s) referenced above. <br />The owner, as defined in chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code <br />requirements. <br />No person may engage in or work at plumbing in the state unless licensed to do so by the Department per s.145.06, <br />stats. <br />The following conditions shall be met during construction or installation and prior to occupancy or use: <br />• Preserve dispersal area prior and during construction to avoid disturbance, compaction and use of the site. <br />• With new construction; it is recommended not to activate the pump in the dose tank until the tanks are pumped <br />prior to homeowner occupancy. <br />• Wastewater generated from contractors cleaning of equipment and tools and/or left over construction <br />products shall not be discharged into the drains discharging to the private onsite wastewater treatment system <br />(POWTS). Waste generated shall be properly disposed of on-site or off site. <br />• Prior to construction of the dispersal area, check the moisture content of the soil to a depth of 8 inches <br />below the system elevation. Smearing and compacting of wet soil will result in reducing the infiltration capacity <br />of the soil. Proper soil moisture content can be determined b rolling olling a soil sample between the hands. If it rolls <br />into a 1/4- inch wire, the site is too wet to prepare. If it crumbles, site preparation can proceed. If the site is too <br />wet to prepare, do not proceed until it dries. <br />• Divert surface water from POWTS Area. <br />• All piping shall conform to SPS Table 384.30-3 and SPS Table 384.30-5 <br />• Insulate building sewer beyond 30 feet per SPS 382.30 (11)(c) <br />