My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2008/06/12 - SANITARY - SAN - Other
Burnett-County
>
Property Files
>
TOWN OF JACKSON
>
5136
>
2008/06/12 - SANITARY - SAN - Other
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2020 9:08:01 PM
Creation date
9/28/2017 7:31:43 AM
Metadata
Fields
Template:
Property Files v2
Document Date
6/12/2008
Document Type 1
SANITARY
Document Type 2
SAN
Document Type 3
Other
Tax ID
5136
Pin Number
07-012-2-40-15-07-5 05-009-016000
Legacy Pin
012420709520
Municipality
TOWN OF JACKSON
Owner Name
CAROLYN TILTON TRUST
Property Address
5579 HAM RIDGE TRL
City
DANBURY
State
WI
Zip
54830
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
2 <br /> System start up shall not occur when soil conditions are frozen at the infiltrative surface. <br /> During power outages pump tanks may fill above normal high water levels. When power is restored the excess wastewater will be <br /> discharged to the dispersal cell(s)in one large dose,overloading the cell(s)and may result in the backup or surface discharge of <br /> effluent. To avoid this situation have the contents of the pump tank removed by a Septage Servicing Operator prior to restoring power <br /> to the effluent pump or contact a Plumber or POWTS Maintainer to assist in manually operating the pump controls to restore normal <br /> levels within the pump tank. <br /> Do not drive or park vehicles over tanks and dispersal cells. Do not drive or park over,or otherwise disturb or compact,the area <br /> within 15 feet of the down slope of any mound or at-grade soil absorption area. <br /> Reduction or elimination of the following from the wastewater stream may improve the performance and prolong the life of the <br /> POWTS: antibiotics;baby wipes;cigarette butts;condoms;cotton swabs;degreasers;dental floss;diapers;disinfectants; fat; <br /> foundation drain(sump pump)water;fruit and vegetable peelings;gasoline;grease;herbicides;meat scraps;medications;oil; <br /> painting products;pesticides;sanitary napkins;tampons;and water softener brine. <br /> ABANDONEMENT <br /> When the POWTS fails and/or is permanently taken out of service the following steps shall be taken to insure that the system is <br /> properly and safely abandoned in compliance with Ch. Comm 83.33, Wisconsin Administrative Code. <br /> • All piping to tanks and pits shall be disconnected and the abandoned pipe openings sealed. <br /> • The contents of all tanks and pits shall be removed and properly disposed of by a Septage Servicing Operator. <br /> • After pumping,all tanks and pits shall be excavated and removed or their covers removed and the void space filled with <br /> soil,gravel or another inert solid material. <br /> Contingency Plan <br /> If the POWTS fails and cannot be repaired the following measures have been,or must be taken,to provide a code compliant <br /> replacement system: <br /> ❑ A suitable replacement area has been evaluated and may be utilized for the location of a replacement soil absorption <br /> system. The replacement area should be protected from disturbance and compaction and should not be infringed upon by <br /> required setbacks from existing and proposed structures,lot lines and wells. Failure to protect the replacement area will result in <br /> the need for a new soil and site evaluation to establish a suitable replacement area. Replacement systems must comply with rules <br /> in effect at that time. <br /> o A suitable replacement area is not available due to setback and/or soil limitations. Barring advances in POWTS <br /> technology a holding tank may be installed as a last resort to replace the failed POWTS. <br /> ❑ The site has not been evaluated to identify a suitable replacement area. Upon failure of the POWTS a soil and site <br /> evaluation must be performed to locate a suitable replacement area. If no replacement area is available a holding tank may be <br /> installed as a last resort to replace the failed POWTS. <br /> Mound and at-grade soil absorption systems may be reconstructed in place following removal of the biomat at the infiltrative <br /> surface. Reconstructions of such systems must comply with the rules in effect at that time. <br /> <Warning> Septic,pump and other treatment tanks may contain lethal gasses and/or insufficient oxygen. Do not <br /> enter a septic,pump or other treatment tank under any circumstances. Death may result. Rescue of a person <br /> from the interior of a tank may be difficult or impossible. <br /> Additional comments: The contingency plan could be to remove the biomat causing system failure and <br /> replace with Astm C 33 Sand ,then clean or replace leaching chambers. This may require an individual <br /> site design and state plan approval. <br /> POWTS INSTALLER POWTS MAINTAINER <br /> Name Daniels Plumbin Name <br /> Phone 715 349-5533 Phone <br /> SEPTAGE SERVICING OPERATOR LOCAL REGULATORY AUTHORITY <br /> Name A+Sanitation Name Burnett Co.Zoning <br /> Phone 715 6564001 Phone 71 349-2138 <br />
The URL can be used to link to this page
Your browser does not support the video tag.