Laserfiche WebLink
PAGE 4OF4 <br />Holding Tank Management Plan <br />IMPORTANT: <br />The owner of this holding tank(s) shall be responsible for its perpetual operation and maintenance pursuant to <br />requirements of SPS 382-384, Wisc. Admin. Code. Pursuant to SPS 383.52 (2), Wisc. Admin. Code, this holding tank(s) <br />shall be considered a human health hazard if not maintained in accordance with this approved management plan. <br />Furthermore, all inspection and maintenance activities shall be performed by a registered POWTS Maintainer in <br />accordance with SPS 383.52 (3), Wisc. Admin. Code. <br />Estimated Daily Wastewater Flow = 0 gpd <br />Inspection Checklist INSPECT EVERY 3 YEARS <br />o type of use <br />o age of system <br />o nuisance factors (i.e. odors, user complaints, etc.) <br />o mechanical malfunction (i.e., pumps, valves, switches, floats, etc.) <br />o material fatigue (i.e., leaks, breaks, corrosion, etc.) <br />o neglect or improper use (i.e., exceeding design capacities, prohibited activities, etc.) <br />o electrical components (i.e., wiring, connections, switches, controls, timers, alarms, etc.) <br />o surface discharge of effluent or sewage back-up into structure served <br />SERVICING FREQUENCY <br />o The tank(s) shall be pumped by a certified septage servicing operator licensed under s. 281.48 Wisc. Stats. <br />when the wastewater in the tank(s) reaches a level of one foot below the inlet invert of the tank(s). <br />Disposal of contents shall be pursuant to NR 113, Wisc. Admin. Code. <br />Tank pumping reports shall be submitted to the proper local government unit in accordance with SPS 383.55 Wis. <br />Admin. Code. Report any component failure or malfunction to: <br />Name of individual or company: pa + / S�a�^/_ Phone: _7%s�S�G��'�ss'S.�- <br />Local government unit: t� X7 Phone: <br />Local government unit address: L % i �'!/ ZIP: <br />Any defective part of this system shall be repaired, replaced, or removed pursuant to SPS 383.51 (1), Wisc. Admin. <br />Code. Repair or replacement of failed or malfunctioning components shall comply with SPS 383, Wisc. Admin. Code. <br />No product for chemical or physical restoration of the POWTS may be used unless approved by the department in <br />accordance with SPS 384, Wisc. Admin. Code. <br />Contingency Plan <br />In the event that any failed component of this holding tank(s) cannot be repaired, it shall be replaced pursuant to a <br />plan submitted to the appropriate agecy for review and approval. <br />System Abandonment <br />If use of this tank(s) is discontinued, it shall be abandoned in accordance with SPS 383.33, Wisc. Admin. Code. <br />