Laserfiche WebLink
HOLDING TANK ,IIIIANAGE:IWEENT PLAN <br />This Private Onsite. Wastewater Treatment Systeri ;POWTS) has been designed, and is to be installed <br />and maintained according to Comm 83, Wis. Adnilri. Code, the Holding Tank Component Ma uql for <br />Private Onsite Wastewater Treatment Systems (%;I: i0 -10571-P; June 11, 1999), and the, <br />County Private Sewage System Ordinance. <br />1. Thi;; POWTS has been designed to accommodate a maximurn daily flow of <br />,20e; gallons of domestic wasiE;iNater per day. <br />2. The owner of this POWTS is respc- ;iible for system operation and maintenance, <br />including all provisions in the attac;md Holding Tank Servicing Contract and <br />Maintenance Agreements. <br />3. Each time the wastewater in the tank reaches 90% of the tank(s) capacity or a <br />level of 12" below the inlet (at which time the alarm will activate), the pumper <br />listed in the current Servicing Contract must be called to empty the tank contents <br />and dispose of them in accordance with NR 113, Wis, Admin. Code. <br />At each pumping the pumper should visually inspect the condition of the tank, <br />risers and manhole cover(s) and verify that any required locks are present. <br />4. The owner may not remove any of the wastes from the holding tanks, or cause <br />such wastes to be removed by any person not authorized to do so under Ch. <br />281, Wis. Statutes. The discharge cf wastes from this holding tank to the ground <br />surface:, including intentional discharges and discharges caused by neglect, <br />constituter a failing private sewage system and may result in issuance of <br />correction orders by the county. <br />5. Anytime a defect is identified or malfunction occurs, it shall be reported to the <br />person(s) identified in the User's Manual for this POW TS. Repair or correction <br />of such i failure car malfunction shall comply with Comm 83, Wis. Admin. Code, <br />and the �„� 27`x` _ County Private Sewage System Ordinance. <br />6. No one should enter a holding tank for any reason without being in full <br />compliance with OSHA standards for entering a confined space. The <br />atmosphere within these tanks may contain lethal gases, and rescue of a person <br />from the interior of the tank may be difficult or impossible. <br />7. In the event that this POWTS fails and cannot be repaired, a code compliant <br />replacement holding tank may be installed in the same location (a new sanitary <br />permit is required for such a replacement). <br />8. If this POW-rS is replaced, or its use discontinued, it shall be abandoned in <br />accordance with Cgmm 83.33, Wis. Admin. Code. <br />