Laserfiche WebLink
• Pump Floats to be set and verified per approved plan. Any changes may result in pump resizing to meet <br /> TDH and GPM Specifications. <br /> • Divert surface water from POWTS Area. <br /> • All piping shall conform to SPS Table 384.30-3 and SPS Table 384.30-5 <br /> • Insulate building sewer beyond 30 feet per SPS 382.30(11)(c) <br /> • Tank Installation to follow all manufacture's recommendations. <br /> • Verify property line(s)prior to installation. <br /> • Well setbacks to meet chs.NR 811 &812. <br /> • Areas that are occupied with rock fragments,tree roots,stumps and boulders reduce the amount of soil <br /> available for proper treatment. If no other site is available,trees in the basal area of the jVftd must be cut off <br /> at ground level. A larger fill area is necessary when any of the above conditions are encountered,to provide <br /> sufficient infiltrative area. <br /> Owner Responsibilities <br /> • The current owner,and each subsequent owner,shall receive a copy of this letter including instructions <br /> relating to proper use and maintenance of the system. Owners shall receive a copy of the appropriate operation <br /> and maintenance manual and/or owner's manual for the POWTS described in this approval SPS 383.54(1). <br /> • In the event this soil absorption system or any of its component parts malfunctions so as to create a health <br /> hazard,the property owner must follow the contingency plan as described in the approved plans. <br /> A copy of the approved plans,specifications and this letter shall be on-site during construction and open to <br /> inspection by authorized representatives of the Department,which may include local inspectors. All permits <br /> required by the state or the local municipality shall be obtained prior to commencement of <br /> construction/installation/operation. <br /> In granting this approval the Division of Industry Services reserves the right to require changes or additions should <br /> conditions arise making them necessary for code compliance.As per state stats 101.12(2),nothing in this review <br /> shall relieve the designer of the responsibility for designing a safe building,structure,or component. <br /> Inquiries concerning this correspondence may be made to me at the telephone number listed below,or at the address <br /> on this letterhead. <br /> The above left addressee shall provide a copy of this letter and the POWTS management plan to the owner and any <br /> others who are responsible for the installation,operation or maintenance of the POWTS. <br /> Sincerely, <br /> r/.t--�r U.2r" <br /> Tim Vander Leest <br /> Private Sewage Plan Reviewer,Division of Industry Services <br /> (920)492-2214,Mon-Fri,6:00 a.m.-3:30 p.m. <br /> tim.vanderleest@wi.gov <br />