My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2019/05/30 - SANITARY - SAN - New Non-Press - SAN-19-70
Burnett-County
>
Property Files
>
TOWN OF MEENON
>
11931
>
2019/05/30 - SANITARY - SAN - New Non-Press - SAN-19-70
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/7/2021 4:00:49 PM
Creation date
10/17/2019 11:40:59 AM
Metadata
Fields
Template:
Property Files v2
Document Date
5/30/2019
Document Type 1
SANITARY
Document Type 2
SAN
Document Type 3
New Non-Press
County Permit Number
SAN-19-70
State Permit Number
614909
Tax ID
11931
Pin Number
07-018-2-39-16-26-2 01-000-011000
Legacy Pin
018332602500
Municipality
TOWN OF MEENON
Owner Name
WILLIAM & SHERYL SCHUMAKER
Property Address
25573 N DAM RD
City
WEBSTER
State
WI
Zip
54893
Previous Owners
WILLIAM & SHERYL SCHUMAKER
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
POWTS OWNER'S MANUAL & MANAGEMENT PLAN Page of -- <br /> Owner INFORMATION SYSTEM SPECIFICATIONS <br /> Owner <br /> Septic Tank Capacity 7h gal ❑ NA <br /> Permit #� <br /> Septic Tank Manufacturer �v �_ _ ❑ NA <br /> DESIGN PARAMETERS Effluent Filter Manufacturer �w � ❑ NA <br /> Number of Bedrooms ❑ NA Effluent Filter Model - — ❑ NA <br /> Number of Public Facility Units ❑ NA Pump Tank Capacity al ❑ NA <br /> Estimated flow (average) "G? gal/day Pump Tank Manufacturer ❑ NA <br /> Design flow (peak), (Estimated x 1.5) gal/day Pump Manufacturer ❑ NA <br /> Soil Application Rate " gal/day/ft2 Pump Model ❑ NA <br /> Standard Influent/Effluent Quality Monthly average* Pretreatment Unit ❑ NA <br /> Fats, Oil & Grease (FOG) 530 mg/L ❑ Sand/Gravel Filter ❑ Peat Filter <br /> Biochemical Oxygen Demand (BODS) :5220 mg/L ❑ NA ❑ Mechanical Aeration ❑ Wetland <br /> Total Suspended Solids (TSS) 5150 mg/L ❑ Disinfection ❑ Other: <br /> Pretreated Effluent Quality Monthly average Dispersal Cell(s) ❑ NA <br /> Biochemical Oxygen Demand (BODS) <_30 mg/L EV In-Ground (gravity) ❑ In-Ground (pressurized) <br /> Total Suspended Solids (TES) 530 mg/L ❑ NA ❑ At-Grade ❑ Mound <br /> Fecal Coliform (geometric mean) <_10' cfu/100ml ❑ Drip-Line ❑ Other: <br /> Maximum Effluent Particle Size Ya in dia. ❑ NA Other: ❑ NA <br /> Other: ❑ NA Other. ❑ NA <br /> *Values typical for domestic wastewater and septic tank effluent. Other: ❑ NA <br /> MAINTENANCE SCHEDULE <br /> Service Event Service Frequency <br /> Inspect condition of tank(s) At least once every: ❑ month(s) (Maximum 3 ears) ❑ NA <br /> ❑ year(s) y <br /> Pump out contents of tank(s) When combined sludge and scum equals one-third (Y) of tank volume ❑ NA <br /> Inspect dispersal cell(s) A- least once every: ❑ month(s) (Maximum 3 years) ❑ NA <br /> ❑ year(s) <br /> Clean effluent filter At least once every: ❑ month(s) ❑ NA <br /> ❑ year(s) <br /> Inspect pump, pump controls & alarm At least once every: ❑ month(s) ❑ NA <br /> ❑ year(s) <br /> Flush laterals and pressure test At least once every: . ❑ month(s) ❑ NA <br /> ❑ year(s) <br /> Other: At least once every: ❑ month(s)❑ year(s) ❑ NA <br /> Other: <br /> ❑ NA <br /> MAINTENANCE INSTRUCTIONS <br /> Inspections of tanks and dispersal cells shall be made by an individual carrying one of the following licenses or certifications: <br /> Master Plumber; Master Plumber Restricted Sewer; POWTS Inspector; POWTS Maintainer; Septage Servicing Operator. Tank <br /> inspections must include a visual inspection of the tank(s) to identify any missing or broken hardware, identify any cracks or leaks, <br /> measure the volume of combined sludge and scum and to check for any back up or ponding of effluent on the ground surface. <br /> The dispersal cell(s) shall be visually inspected to check the effluent levels in the observation pipes and to check for any ponding <br /> of effluent on the ground surface. The ponding of effluent on the ground surface may indicate a failing condition and requires the <br /> immediate notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum in any tank equals one-third (Y3) or more of the tank volume, the entire <br /> contents of the tank shall be removed by a Septage Servicing Operator and disposed of in accordance with chapter NR 113, <br /> Wisconsin Administrative Code. <br /> All other services, including but not limited to the servicing of effluent filters, mechanical or pressurized components, pretreatment <br /> units, and any servicing at intervals of 512 months, shall be performed by a certified POWTS Maintainer. <br /> A service report shall be provided to the local regulatory authority within 10 days of completion of any service event. <br />
The URL can be used to link to this page
Your browser does not support the video tag.