Laserfiche WebLink
HOLDING TANK SPECIFICATIONS <br /> 3 Number of bedrooms <br /> Non-residential estimated flow(gpd) <br /> 2000.0 Minimum holding tank volume required (gal) <br /> 2000.07 Proposed holding tank capacity(gal) <br /> Wieser Concrete Tank Manufacturer <br /> WLP2000-MR Tank model number <br /> Level-Alarm Alarm manufacturer <br /> DLV Alarm model number <br /> Tank Dimensions and Data Tank Anchor Calculations <br /> 8'x13.67' X for round tank 21120 Ibs Weight of tank and cover <br /> 36.0 Liquid depth below inlet invert(in) F_-1.50 Safety factor <br /> 8.0 Maximum depth of soil cover(ft) 24078 Ibs Weight of anchor required <br /> 53.0 Height(in) Outside 23.0 in Soil cover req. for anchor or <br /> 164.0 Length (in) Dimensions 5.9 yd3 Concrete counter weight <br /> 96.0 Width (in) I Only <br /> HOLDING TANK CROSS SECTION <br /> manhole cover with <br /> locking device and finished vent cap <br /> junction warning label grade <br /> box <br /> 4"min. 12"min. <br /> 24 in. <br /> Manhole and vent locations <br /> conduit may be reversed. vent pipe <br /> 18"min. <br /> building sewer <br /> ----service � 12.01n----------------------------- <br /> inlet <br /> blind plug alarm on Note: All tank joints, and <br /> to seal joints between tank <br /> outlet openings and piping are <br /> Electrical as per 24.0 in. sealed watertight. All pipe <br /> NEC 300 and vent materials comply <br /> and Comm 16 with Comm 84. <br /> 3 in. bedding under tank. Tank is anchored as necessary to negate buoyancy. <br /> Project: Bonnie and Harold Moline 10518 State Rd. 70 <br /> Transaction Number: Page 2 of 4 <br />