My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2020/04/27 - SANITARY - SAN - Repl Non-Press - SAN-20-45
Burnett-County
>
Property Files
>
TOWN OF JACKSON
>
5387
>
2020/04/27 - SANITARY - SAN - Repl Non-Press - SAN-20-45
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/29/2020 12:46:28 PM
Creation date
4/29/2020 12:43:35 PM
Metadata
Fields
Template:
Property Files v2
Document Date
4/27/2020
Document Type 1
SANITARY
Document Type 2
SAN
Document Type 3
Repl Non-Press
County Permit Number
SAN-20-45
State Permit Number
623702
Tax ID
5387
Pin Number
07-012-2-40-15-18-5 05-014-012000
Legacy Pin
012421802905
Municipality
TOWN OF JACKSON
Owner Name
DUANE & KAY SELLMAN REV LIVING TRUST
Property Address
28584 COUNTY RD T
City
WEBSTER
State
WI
Zip
54893
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PAGE 4 OF 4 <br /> In-ground Gravity Management Plan <br /> IMPQRTANT: <br /> The owner of this in-ground gravity system shall be responsible for its perpetual operation and maintenance pursuant to <br /> requirements of SPS 382-384,Wsc.Admin. Code. Pursuant to SPS 383.52(2),Wisc.Admin.Code,this system shall <br /> be considered a human health hazard if not maintained in accordance with this approved management plan. <br /> Furthermore,all inspection and maintenance activities shall be performed by a registered POWTS Maintainer in <br /> accordance with SPS 383.52(3),Wisc.Admin. Code. <br /> Maximum Dispersal Area Operating Limits: <br /> Design Flow= gpd; BPDs S 220 nom."'; TSS S 1501; ' <br /> mgL" , FOG S 30 mgL" <br /> Inspection Checklist INSPECT EVERY 3 YEARS <br /> o type of use <br /> o age of system <br /> o nuisance factors(ie odors,user complaints,etc.) <br /> o mechanical malfunction(i.e., pumps,valves, switches,floats, etc.) <br /> o material fatigue(i e.,leaks,breaks, corrosion, etc.) <br /> o solids volume in anaerobic treatment tank(s)and any distribution appurtenance(s)(i.e.,distribution I drop boxes) <br /> o neglect or improper use(ie., exceeding design capacities,prohibited activities,etc.) <br /> o extent of ponding in distribution cell prior to dosing <br /> o dosing irregularities-if applicable(ie.,pump re-cyclnig,float switch settings, etc.) <br /> o electrical components-if applicable(i.e.,wiring,connections,switches,controls,timers,alarms,etc.) <br /> o distribution lateral or lateral orifice plugging (measure lateral distal pressure—compare to design specification) <br /> o surface discharge of effluent or sewage back-up into structure served <br /> Maintenance Checklist MAINTAIN EVERY 3 YEARS(or when necessary) <br /> o Septic and dose tanks)shall be pumped by a certified septage servicing operator lid under s. 281.48 Wis. <br /> Stats.when the volume of solids in the tank(s)exceeds one-third(113)the liquid volume of the tanks)or <br /> as required by local ordinance. Disposal of contents shall be pursuant to NR 113,Wisc.Admin.Code. <br /> o Effluent filters)shall be inspected every 3 years and shall be cleaned when necessary to remove any <br /> accumulated solids according to manufacturer's specifications. A servicing period will always be greater than 12 <br /> months. <br /> System maintenance reports shall be submitted to the proper local government unit in accordance with <br /> SPS 383.55 Wisc.Admin.Code. Report any component failure or malfunction to: <br /> Name of individual or company: C.D,ty - C($Oi) ! Gum S VI/ Phoria: 715- " 04 <br /> Local government unit L3 WNE7T 6, ZD LAI( Phone: 7/S--31:71?— Z)O? <br /> Local government unit address: .5'/N, L'W- ZIP: /?7 2, <br /> Any defective part of this system shall be repaired, replaced, or removed pursuant to SPS 383.51 (1),Wisc.Admin_ <br /> Code. Repair or replacement of failed or malfunctioning components shall comply with SPS 383,Wise.Admin.Code. <br /> No product for chemical or physical restoration of the POWTS may be used unless approved by the department in <br /> accordance with SPS 384,Wisc.Admin. Code. <br /> Contingency Plan <br /> In the event that any failed treatment component of this POWTS cannot be repaired,it shall be replaced pursuant to <br /> a plan submitted to the appropriate agency for review and approval. A failed in-ground dispersal component may be <br /> abandoned and replaced by a code-complying dispersal component in a pie-determined area of suitable sods. <br /> System Abandonment <br /> If use of this POWfS is discontinued, it shall be abandoned in accordance with SPS 383.33,Wisc.Admin.Code. <br />
The URL can be used to link to this page
Your browser does not support the video tag.