Laserfiche WebLink
PAGE 4 OF 4 <br /> In-ground Gravity Management Plan <br /> IMPQRTANT: <br /> The owner of this in-ground gravity system shall be responsible for its perpetual operation and maintenance pursuant to <br /> requirements of SPS 382-384,Wsc.Admin. Code. Pursuant to SPS 383.52(2),Wisc.Admin.Code,this system shall <br /> be considered a human health hazard if not maintained in accordance with this approved management plan. <br /> Furthermore,all inspection and maintenance activities shall be performed by a registered POWTS Maintainer in <br /> accordance with SPS 383.52(3),Wisc.Admin. Code. <br /> Maximum Dispersal Area Operating Limits: <br /> Design Flow= gpd; BPDs S 220 nom."'; TSS S 1501; ' <br /> mgL" , FOG S 30 mgL" <br /> Inspection Checklist INSPECT EVERY 3 YEARS <br /> o type of use <br /> o age of system <br /> o nuisance factors(ie odors,user complaints,etc.) <br /> o mechanical malfunction(i.e., pumps,valves, switches,floats, etc.) <br /> o material fatigue(i e.,leaks,breaks, corrosion, etc.) <br /> o solids volume in anaerobic treatment tank(s)and any distribution appurtenance(s)(i.e.,distribution I drop boxes) <br /> o neglect or improper use(ie., exceeding design capacities,prohibited activities,etc.) <br /> o extent of ponding in distribution cell prior to dosing <br /> o dosing irregularities-if applicable(ie.,pump re-cyclnig,float switch settings, etc.) <br /> o electrical components-if applicable(i.e.,wiring,connections,switches,controls,timers,alarms,etc.) <br /> o distribution lateral or lateral orifice plugging (measure lateral distal pressure—compare to design specification) <br /> o surface discharge of effluent or sewage back-up into structure served <br /> Maintenance Checklist MAINTAIN EVERY 3 YEARS(or when necessary) <br /> o Septic and dose tanks)shall be pumped by a certified septage servicing operator lid under s. 281.48 Wis. <br /> Stats.when the volume of solids in the tank(s)exceeds one-third(113)the liquid volume of the tanks)or <br /> as required by local ordinance. Disposal of contents shall be pursuant to NR 113,Wisc.Admin.Code. <br /> o Effluent filters)shall be inspected every 3 years and shall be cleaned when necessary to remove any <br /> accumulated solids according to manufacturer's specifications. A servicing period will always be greater than 12 <br /> months. <br /> System maintenance reports shall be submitted to the proper local government unit in accordance with <br /> SPS 383.55 Wisc.Admin.Code. Report any component failure or malfunction to: <br /> Name of individual or company: C.D,ty - C($Oi) ! Gum S VI/ Phoria: 715- " 04 <br /> Local government unit L3 WNE7T 6, ZD LAI( Phone: 7/S--31:71?— Z)O? <br /> Local government unit address: .5'/N, L'W- ZIP: /?7 2, <br /> Any defective part of this system shall be repaired, replaced, or removed pursuant to SPS 383.51 (1),Wisc.Admin_ <br /> Code. Repair or replacement of failed or malfunctioning components shall comply with SPS 383,Wise.Admin.Code. <br /> No product for chemical or physical restoration of the POWTS may be used unless approved by the department in <br /> accordance with SPS 384,Wisc.Admin. Code. <br /> Contingency Plan <br /> In the event that any failed treatment component of this POWTS cannot be repaired,it shall be replaced pursuant to <br /> a plan submitted to the appropriate agency for review and approval. A failed in-ground dispersal component may be <br /> abandoned and replaced by a code-complying dispersal component in a pie-determined area of suitable sods. <br /> System Abandonment <br /> If use of this POWfS is discontinued, it shall be abandoned in accordance with SPS 383.33,Wisc.Admin.Code. <br />