Laserfiche WebLink
I(applicant)hereby make application to the Land Use and Information Committee for a Conditional Use Permit(CUP) <br /> for the following: <br /> The previous owner,Jan Berghoff applied for and received a conditional use permit CUP-19-25 from Burnett County on November 5th <br /> 2019.This was to build 4 storage units, a possible cabin,and an area in the middle of the field for possible future units.Jan Berghoff <br /> never built any storage units. <br /> IceOut LLC purchased the property in March 2020 from Jan Berghoff. <br /> After talking with the Burnett County Zoning Administrator Jason Towne about our building plans he said that we would need to apply <br /> for a new CUP due to changes in the layout of the buildings(locations/size/number)that we would like to build on this property. <br /> We would like to have some flexibility in the size of the buildings to be built as we cannot adequately forecast demand for certain sized <br /> storage units. We believe the lengths of the building to be approximately 200-215 feet long depending on building manufacturer and unit <br /> sizes.Number of units configured and wall widths affect building length. For storage units we anticipate sizing them as 5x5,5x10, <br /> l 0x10, 10x20, 12x24, 12x32, 12x40.This would result in approximate building widths(due to manufacturer differences)20',24',32',40'. <br /> (Not including roof overhang). If demand for certain sized units was different than our anticipated build-out we would like to have the <br /> flexibility to change a building width either larger or smaller than what we show on the diagram. For instance,we show a 24x210 foot <br /> building and decide to build a 20x210 foot building. <br /> A plot plan drawing is required. Plot plan shall be drawn with a scale preferably at 1"=20' or multiples of <br /> 10', scale shall not exceed 1"=50', unless approval from Zoning Administrator for a different scale is <br /> allowed. Note the scale used on the drawing. Plot plan drawing shall be on letter or legal size paper with <br /> North being at the top of the page. (Make sure all items below are shown): <br /> ❑ Property lines,road right-of-ways, and road centerlines including distances to property lines, road right-of-ways and <br /> road centerlines for all existing and proposed structures on the parcel <br /> ❑ Show area to used for the proposed Conditional Use <br /> ❑ All existing uses on parcels adjacent to the parcel for this request <br /> ❑ All existing zoning districts on parcels adjacent to the parcel for this request <br /> ❑ Vegetation proposed to be removed or disturbed <br /> ❑ Ordinary High Water Mark(OHWM) and distances to it from all existing and proposed structures; must show all <br /> within 200 ft of structures <br /> ❑ Floodplain and wetland boundaries and distances to them from all existing and proposed structures;must show all <br /> within 200 ft of structures <br /> ❑ Dimensions, locations and setbacks of all existing and proposed structures including all <br /> decks/porches/walkways/etc; must show dimensions for ALL items <br /> ❑ Existing and proposed utilities and utility easements <br /> ❑ Sanitary system,drainfield and well with distances to property lines,OHWM,wetlands,floodplains,existing and <br /> proposed buildings <br /> ❑ Location and extent of filling/grading <br /> ❑ Location and type of erosion control measures <br /> ❑ Any other construction related to your project <br /> ❑ North arrow <br /> Page 2 of 4 <br /> Burnett County, WI Conditional Use Permit (CUP) Application —Rev 11/2019 <br />