Laserfiche WebLink
PRIVATE ONSITE WASTEWATE°' TREATMENT SYSTEM MANAGEMENT PLAN <br /> SEPTIC TANK AND GRAVITY RN-GROUND SOIL ABSORPTION tC 1MiPONENT <br /> Pursuant to SPS 383.54 WI §, each Private Onsite Wastewater Treatment System (POWTS) shall include <br /> information and procedures for maintaining the system within the parameters of SPS 383 and 384,and the <br /> conditions of approval by i I le department, agent, or governmental unit. The approved plans aid permits <br /> for the system are oik nit at the county zoning office. <br /> This management plan complies with SPS 383.54 WI § and the In-Ground Soil Absorption Component <br /> Manual for Private Onsite Wastewater Treatment System SBD-10705-P(N. 01/01: R. 10/12). <br /> Table 1: SysteqI 1 esign Specifications <br /> Sanitary Permit Number <br /> Number of Bedrooms ,:7/ <br /> Design Flow—Peak(gpd) 40 p <br /> Estimated Flow—Average(gpd) lie 0 <br /> Septic Tank Capacity(gal) /_300 <br /> Soil Absorption Component Size(ft2) 1� '- r' E FAseci .-/g c: <br /> Type ofWastewvater 19�/n`' �, <br /> Table 2: Soil Absorption (Codi ponent—Limits of Reliable Operation <br /> Septic Tank Component Soil Absorption Component <br /> Design Flow—Peak(gpd) <br /> Maximum Influent Particle Size(in) N/A 1/8 <br /> Maximum B011)5(mg/L) N/A 220 <br /> Maximum TSS(mg/L) N/A 150 <br /> Maximum 4O,G.1 N/A 30 <br /> Table 3: Mai ctenance Schedule <br /> Septic Tank Inspect and service once every 3 years <br /> Outlet Filter Should inspect once a year and clean once every year <br /> Soil Absorption Component Inspect once every 3 years <br /> SEPTIC TANK <br /> An individual certified to service septic tanks under s. 281.48, Stats, shall maintain the septic tank. The <br /> contents of the septic tank shall be disposed of in accordance with NR 113, Wis. Adm. Code (Servicing <br /> Septic or Holding Tanks, Pumping Chambers, Grease Interceptors, Seepage Beds, Seepage Pits, Seepage <br /> Trenches, privies or5PortableIRestroors). <br /> The operating condition of the septic tank and outlet filter shall be assessed at least once every 3 years by <br /> inspection. The outlet falter shall be cleaned as necessary to ensure proper operation. The filter cartridge <br /> should not be removed unless provisions are made to retain solids in the tank that may slough off the filter <br /> when removed from its enclosure. If the filter is equipped with an alarm,the filter shall be serviced if the <br /> alarm is activated continuously. Intermittent filter alarms may indicate surge flows or an impending <br /> continuous alarm. The septic tank shall have is contents removed when the volume of scum and sludge in <br /> the tank exceeds I//j"t►q.liq ui4.volume of the tank. If the contents of the tank are not removed at the time <br /> of an assessment, maintenance personnel shall advise the owner of when the next service needs to be <br /> performed to maintain less than maximum scum and sludge accumulation in the tank. <br />