Laserfiche WebLink
Safety and Buildings <br /> commerce.wi. ov 10541N RANCH ROAD <br /> g HAYWARD WI 54843 <br /> Contact Through Relay <br /> isconsin w .commerce.wi.gov/sb/ <br /> Department of Commerce www.wisconsin.gov <br /> Scott Walker,Governor <br /> Paul F.Jadin,Secretary <br /> June 08,2011 <br /> CUST ID No. 225851 ATTN POWTS Inspector <br /> RICHARD HOPKINS ZONING OFFICE <br /> HOPKINS SAND& GRAVEL BURNETT COUNTY SPIA <br /> 27760 HWY 35 7410 CTH K#102 <br /> WEBSTER WI 54893 SIREN WI 54872 <br /> CONDITIONAL APPROVAL <br /> PLAN APPROVAL EXPIRES: 06/08/2013 Identification Numbers <br /> Transaction ID No. 1949245 <br /> SITE: Site ID No. 768127 <br /> Frederick&Marcia Altaffer Please refer to both identification numbers, <br /> 20528 Rangeline Rd above, in all correspondence with the aoenc . <br /> Town of Trade Lake <br /> Burnett County <br /> , S30,T37N,R18W <br /> FOR: <br /> Description: Aerobic treatment unit to mound,3 bedroom residence ?'C <br /> Object Type: POWTS Component Manual Regulated Object ID No.: 1319242 <br /> Maintenance required; 450 GPD Flow rate; 18 in Soil minimum depth to limiting factor from original grade; System(s): Ci0 d <br /> Mound Component Manual-Version 2.0, SBD-10691-P(N.01/01),Pressure Distribution Component Manual-Version <br /> 2.0, SBD-10706-P(N.01/01), SSWMP Pub. 9.6; Aerobic Treatment Unit, Effluent Filter <br /> JEPARC <br /> The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes �I <br /> and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. This system is to be constructed �^ <br /> and located in accordance with the enclosed approved plans and with any component manual(s)referenced above. <br /> The owner,as defined in chapter 101.01(10), Wisconsin Statutes,is responsible for compliance with all code <br /> requirements. <br /> No person may engage in or work at plumbing in the state unless licensed to do so by the Department per s.145.06, <br /> stats. <br /> The following conditions shall be met during construction or installation and prior to occupancy or use: <br /> Key Item(s) <br /> • In the event this soil absorption system or any of its component parts malfunctions so as to create a health <br /> hazard,the property owner must follow the contingency plan as described in the approved plans. In addition,the <br /> owner must insure that the operation,maintenance and monitoring duties as described in section VIII of the <br /> mound component manual are complied with.A copy of this information must be given to the owner upon <br /> completion of the project. <br /> • The float switch shall be a type that does not contain mercury.2009 Wisconsin Act 44 prohibits the installation <br /> of float switches or relays that contain mercury. <br /> • The distribution cell is designed for wastewater strength with monthly averages of less than or equal to 20 <br /> mg/L of fats, oils and grease, less than or equal to 30 mg/L of biochemical oxygen demand and 30 mg/L total <br /> suspended solids and fecal colifrom levels of less than 10,000 cfu/100 ml. <br />