PAGE 3 OF 4 <br /> HOLDING TANK SPECIFICATIONS <br /> (No Scale) <br /> Weatherproof 12"Min.or 2.0 ft above <br /> Junction and Approved Established Flood Elevation <br /> Alarm Box Vent Cap (typical) <br /> Electrical must comply with + Approved Locking Manhole <br /> 11 <br /> SPS 316 and NEC 300 4"0 Vent Pipe with Warning Label Attached <br /> --Conduit >10 ft from (typical) 4"Min.or 2.0 ft above <br /> Building I Established Flood Elevation <br /> f (typical) <br /> f - Airtight Seal <br /> a Finished Grade <br /> 18"Min. <br /> (typical) <br /> Inlet Inlet Invert Watertight <br /> Approved Joints with Plug <br /> Approved Pipe 3 ft onto Max. 12"or 90%of total volume <br /> Solid Ground if more than one tank <br /> a <br /> ° Alarm-On <br /> e <br /> e <br /> HOLDING TANK <br /> VOLUME = 2000 gal <br /> a d <br /> 3"Approved Bedding Material Beneath Tank <br /> TANK MANUFACTURER: Wieser <br /> Anchor tank as necessary <br /> pursuant to SPS 383.43(8)(g) <br /> Ballast Weight= [(cu.ft.tank.vol x 62.4 Ibs/cu.ft)- Ibs.tank.wt]x 1.5 <br /> Ballast Weight= [( 31094 Cu.ft. x 62.4 Ibs/cu.ft)- 22230 Ibs] x 1.5 = 13296 Ibs <br />