Laserfiche WebLink
PAGE 4 OF 4 <br /> Holding Tank Management Plan <br /> IMPORTANT: <br /> The owner of this holding tank(s) shall be responsible for its perpetual operation and maintenance pursuant to <br /> requirements of SPS 382-384,Wisc.Admin. Code. Pursuant to SPS 383.52(2),Wisc. Admin. Code, this holding tank(s) <br /> shall be considered a human health hazard if not maintained in accordance with this approved management plan. <br /> Furthermore, all inspection and maintenance activities shall be performed by a registered POWTS Maintainer in <br /> accordance with SPS 383.52(3),Wisc. Admin. Code. <br /> Estimated Daily Wastewater Flow= 100 gpd <br /> Inspection Checklist INSPECT EVERY 3 YEARS <br /> o type of use <br /> o age of system <br /> o nuisance factors (i.e. odors, user complaints, etc.) <br /> o mechanical malfunction (i.e., pumps, valves, switches,floats, etc.) <br /> o material fatigue(i.e., leaks, breaks, corrosion, etc.) <br /> o neglect or improper use (i.e., exceeding design capacities, prohibited activities, etc.) <br /> o electrical components(i.e.,wiring, connections, switches, controls, timers, alarms, etc.) <br /> o surface discharge of effluent or sewage back-up into structure served <br /> SERVICING FREQUENCY <br /> o The tank(s)shall be pumped by a certified septage servicing operator licensed under s. 281.48 Wisc. Stats. <br /> when the wastewater in the tank(s) reaches a level of one foot below the inlet invert of the tank(s). <br /> Disposal of contents shall be pursuant to NR 113,Wisc. Admin. Code. <br /> Tank pumping reports shall be submitted to the proper local government unit in accordance with SPS 383.55 Wis. <br /> Admin. Code. Report any component failure or malfunction to: <br /> Name of individual or company: Schmitz Excavating and Septic LLC phone: 715-520-2434 <br /> Local government unit: Burnett Phone: 715-349-2109 <br /> Local government unit address: Siren WI ZIP: 54872 <br /> Any defective part of this system shall be repaired, replaced, or removed pursuant to SPS 383.51 (1),Wisc. Admin. <br /> Code. Repair or replacement of failed or malfunctioning components shall comply with SPS 383,Wisc. Admin. Code. <br /> No product for chemical or physical restoration of the POWTS may be used unless approved by the department in <br /> accordance with SPS 384,Wisc.Admin. Code. <br /> Contingency Plan <br /> In the event that any failed component of this holding tank(s)cannot be repaired, it shall be replaced pursuant to a <br /> plan submitted to the appropriate agecy for review and approval. <br /> System Abandonment <br /> If use of this tank(s)is discontinued, it shall be abandoned in accordance with SPS 383.33,Wisc. Admin. Code. <br />