Laserfiche WebLink
Page 1 a+b of 5 <br /> indicates that restaurants and other food preparation/processing facilities that prepare food as a <br /> major part of the operation are expected to produce high wastewater that will exceed the <br /> maximum allowable concentrations. For the purpose of this policy these facilities will be <br /> considered High-Strength Wastewater Producing Facilities. These facilities can be either new or <br /> existing. Unless wastewater documentation can be provided to prove otherwise the Department <br /> assumes the following: <br /> 1. FOG—200 mg/L <br /> 2. BODS— 1200 mg/L <br /> 3. TSS —220 mg/L <br /> The second category created by the Dept. is what is known as At-Risk Wastewater Producing <br /> Facilities. These facilities are public or commercial and have food preparation as part of their <br /> operation,but less than that of a full service restaurant, a different approach will be accepted <br /> provided that the local government unit (usually the county) in which the POWTS is proposed to <br /> be located concurs in writing with the additional oversight. This alternative approach relies less <br /> on presumptions of wastewater strength and more on monitoring the performance of the system <br /> and taking a proactive approach should persistent ponding be observed. <br /> For the purpose of this POWTS Design the At-Risk Wastewater Producing Facility category <br /> would be where this commercial use as a campground bar or tavern would fall as food <br /> preparation will only be a part of the operation. Based on the information provided by the owners <br /> regarding the proposed types of food to be served and the DHS license to be applied for as a <br /> "Pre-packaged restaurant", I feel that this facility with the additional county oversight required <br /> along with the performance monitoring POWTS management, maintenance and contingency <br /> plan proposed while adding in the seasonality of the business will be sufficient in protecting the <br /> system from premature failure while properly disposing of the wastewater generated from this <br /> proposed commercial establishment. <br /> The treatment chain includes a 1000 gallon grease interceptor(general plumbing permit applied <br /> for) to collect the wastewater from the kitchen. The bathroom wastewater will exit the building <br /> from a separate location and will merge with the kitchen wastewater into a 1565 gallon septic <br /> tank with a Poly-Lok PL-525effluent filter. The effluent will gravity flow to total of three <br /> dispersal cells consisting of 22 leaching chambers per cell for a total of 66. The cells will be 3 ft. <br /> x 90 ft. in length. <br /> I believe that the sanitary design proposed will adequately treat and disperse the wastewater <br /> generated from this bar and through proper monitoring of the dispersal cells and system <br /> maintenance it will satisfy SPS 383.40 for the purpose of safeguarding the public health, <br /> protecting the waters of the state and will comply with the design performance standards. <br /> Thank you for your consideration of this proposal. <br /> Keith E. Stoner Designer#1575-007 <br /> Revised 3-23-15 <br /> Trans. ID#2521310 <br />