Laserfiche WebLink
POWTS OWNER'S MANUAL & MANAGEMENT PLAN Page of_ <br /> FILE INFORMATION SYSTEM SPECIFICA IONS <br /> Owner Just Tank Manufacturer: ">] i C-s -r ■ NA <br /> Permit# it Septic ❑Dose ❑ Holding Volume: S Z' (gal) <br /> ESIGN PARAMETERS Tank Manufacturer: 19 NA <br /> Number of Bedrooms: 2 ❑ NA ❑ Septic ❑ Dose ❑ Holding Volume: (gal) <br /> Number of Public Facility Units: ❑ NA Vertical Distance Tank Bottom(s)to Service Pad: (ft) <br /> Estimated(average)Flow: (gal/day) Horizontal Distance Tank(s)to Service Pad: (ft) <br /> Specific servlCing mechanics must be provided if vertical is>15 feet or <br /> Design(peak)Flow=(estimated x 1.5): ()^) (gal/day) If horizontal is>150 feet.Specific instructions to be provided on back. <br /> In Situ Soil Application Rate: 7 (gal/day/ftz) Effluent Filter Manufacturer: �f��y > 0 NA <br /> Standard(Domestic)Influent/Effluent Monthly average Effluent Filter Model: U <br /> Fats,Oil&Grease(FOG) 5.30 mg/L Pump Manufacturer: <br /> Biochemical Oxygen Demand(BODS) s220 mg/L ❑NA r NA <br /> Total Suspended Solids(TSS) s150 m /L Pump Model: <br /> High Strength Influent/Effluent Monthly average Pretreatment Unit <br /> (FOG) >30 mg/L Manufacturer: <br /> (BOD5) >220 mg/L lid NA III NA <br /> TSS >150 m /L ❑ Mechanical Aeration ❑Peat Filter <br /> ❑ Disinfection ❑Wetland <br /> Pretreated Effluent Monthly average ❑ Sand Gravel Filter ■ other: <br /> (BODS) s30 mg/L Soil Absorption System <br /> (TSS) s30 mg/L 0 NA <br /> Fecal Coliform(geometric mean sIa, N'In-Ground(gravity) ■ In-Ground(pressure) ■ NA <br /> Maximum Effluent Particle Size t8 in dia. ElNA ❑ At-Grade ❑Mound <br /> ❑ Drip-Line Other: <br /> Other: 9 NA Other m NA <br /> Service Event Service Frequency <br /> F Pump out contents of tank(s) U77en combined sludge and scum equals one-third(3)of tank volume <br /> ❑ When the high water alarm is activated <br /> Inspect condition of tank(s) At least once every: 7 � ear(s)s) (Maximum 3 years) ❑ NA <br /> Inspect dispersal cell(s) At least once every: 3 ❑ month(s)21'year(s) (Maximum 3 years) ❑ NA <br /> Clean effluent filter At least once eve ❑ month(s) <br /> every: Ir year(s) ❑ NA <br /> Inspect pump,pump controls&alarm At least once every: ❑ month(s) <br /> ❑ year(s) <br /> Flush laterals and pressure test At least once every: o month <br /> O year(s)(s) lid NA <br /> Other: At least once every: ❑ month(s) 9 NA <br /> ❑ year(s) <br /> Other: <br /> r NA <br /> MAINTENANCE INSTRUCTIONS <br /> Inspections of tanks and soil absorption systems shall be made by an individual carrying one of the following licenses or certifications: <br /> Master Plumber, Master Plumber Restricted Sewer, POWTS Inspector, POWTS Maintainer or Septage Servicing Operator(pumper). <br /> Tank inspections must include a visual inspection of the tank(s)to identify any missing or broken hardware, identify any cracks or leaks, <br /> measure the volume of combined sludge and scum and a check for any back up or ponding of effluent on the ground surface.The soil <br /> absorption system shall be visually inspected to check the effluent levels in the observation pipes and to check for any ponding of effluent <br /> on the ground surface.The ponding of effluent on the ground surface may indicate a failing condition and requires the immediate <br /> notification of the local regulatory authority. <br /> When the combined accumulation of sludge and scum in any treatment tank equals one-third(%)or more of the tank volume,the entire <br /> contents of the tank shall be removed by a Septage Servicing Operator(pumper)and disposed of in accordance with chapter NR 113, <br /> Wisconsin Administrative Code. <br /> All other services, including but not limited to the servicing of effluent filters, mechanical or pressurized components,pretreatment units, <br /> and any servicing at intervals of_12 months,shall be performed by a certified POWTS Maintainer. <br /> A service report shall be provided to the local regulatory authority within 30 days of completion of any service event. <br /> GMW-005(02/05) <br />