Laserfiche WebLink
HOLDING TANK SPECIFICATIONS <br /> 2 Number of bedrooms <br /> Non-residential estimated flow(gpd) <br /> 2000.0 Minimum holding tank volume required (gal) <br /> 3000.0 JProposed holding tank capacity (gal) <br /> weiser Tank Manufacturer <br /> 30001p Tank model number <br /> Rhombus SJE Alarm manufacturer <br /> Tank Alert 101-01H Alarm model number <br /> Tank Dimensions and Data Tank Anchor Calculations <br /> X for round tank 25280 Ibs Weight of tank and cover <br /> 43.0 Liquid depth below inlet invert(in) 1.50 Safety factor <br /> 8.0 Maximum de th of soil cover(ft) 38766 Ibs Weight of anchor required <br /> 63.0 Height(in) Outside 35.7 in Soil cover req.for anchor or <br /> 184.0 Length (in) Dimensions 9.6 yd3 Concrete counter weight <br /> 102.0 Width (in) Only <br /> HOLDING TANK CROSS SECTION <br /> manhole cover with <br /> locking device and finished vent cap <br /> junction warning label grade <br /> box —> � — <br /> �4"min. 12"min. <br /> E--23 in. <br /> Manhole and vent locations <br /> conduit — > may be reversed. vent pipe 18"min. <br /> tether weight_ _ _ _ _ _ .._._._-_._._._`✓..... - <br /> 120 in. building sewer <br /> . <br /> service inlet <br /> blind plug alarm on A Note: All tank joints, and <br /> to seal joints between tank <br /> outlet openings and piping are <br /> Electrical as per 31.0 in. sealed watertight. All pipe <br /> NEC 300 and vent materials comply <br /> and SPS 316 with SPS 384. <br /> 3 in.bedding under tank. Tank is anchored as necessary to negate buoyancy. <br /> Project: keith burkett garage <br /> Transaction Number: Page 2 of 4 <br />