Laserfiche WebLink
HOLDING TANK MANAGEMENT PLAN <br /> This Private Onsite Wastewater Treatment System (POWTS) has been designed, and is to be installed and <br /> maintained according to SPS 383, Wis. Admin. Code, the Holding Tank Component Manual (SBD-10855-P <br /> N. 03/07, R. 01/12), and the Burnett County Sanitary Ordinance. <br /> 1. This POWTS is designed to accommodate a wastewater flow of 40.0 to 600.0 gpd. <br /> 2. The owner of this POWTS is responsible for system operation and maintenance, including all provisions in <br /> the attached Holding Tank Servicing Contract and Maintenance Agreements. <br /> 3. Each time the wastewater in the tank reaches 90% of the tank(s)capacity or a level of 12" below the inlet <br /> (at which time the alarm will activate), the pumper listed in the current Service Contract must be called to <br /> empty the tank's contents and dispose of them in accordance with NR 113, Wis. Adm. Code. <br /> 4. At each service event, the service provider should visually inspect the condition of the tank, risers and <br /> manhole cover(s) and verify that the alarm system functions and manhole locking devices are present. <br /> Discrepancies are reported to the owner in a timely manner for corrective action. All corrective actions <br /> shall comply with the county sanitary ordinance and SPS 383 and 384 Wis. Adm. Code, <br /> 5. All service events or inspections of this POWTS shall be reported to the county within 30 days. <br /> 6. The owner may not remove any of the wastes from the holding tank(s), or cause such wastes to be <br /> removed by any person not authorized to do so under Ch. 281, Wis. Statutes. The discharge of wastes <br /> tank to the ground surface, including intentional discharges and discharges caused by neglect, constitutes <br /> a failing POWTS and may result in issuance of correction orders or a citation by the county or state. <br /> 7. No one should enter a holding tank for any reason without being in full compliance with OSHA standards <br /> for entering a confined space. The atmosphere within these tanks may contain lethal gases, and rescue <br /> of a person from the interior of the tank may be difficult or impossible. <br /> 8. In the event that this POWTS fails and cannot be repaired, a code compliant replacement holding tank <br /> may be installed in the same location (a new sanitary permit is required for such a replacement). Con- <br /> nection to municipal services would also be considered at this time if they are deemed available to the <br /> property. <br /> 9. If this POWTS is replaced, or its use discontinued, components no longer in use it shall be abandoned in <br /> accordance with SPS 383.33 Wis. Adm. Code. <br /> 10. If there is a problem with, or question about this installation, the following persons may be contacted: <br /> a. Installer......................... cullen hanson Phone: 7154104100 <br /> b. Service Provider............... Olson sewer service Phone: <br /> c. Co. Zoning or Health Dept. burnett county Phone: <br /> 11. <br /> Project: keith burkett garage <br /> Transaction Number: Page 4 of 4 <br />